Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

77 results
Display

Application of tin ion-plating to the orthodontic appliance

Kwon OW, Kim KH

  • KMID: 2271224
  • Korean J Orthod.
  • 1991 Mar;21(1):7-16.
To estimate the possibility of the application of TiN ion-plating to the orthodontic appliance, colorimetric properties, and characteristics of ion-plated film as well as adhesive strength of TiN film to...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A study on metal release of tin ion-plated stainless steel orthodontic appliances

Kim MS, Sung JH, Kwon OW

  • KMID: 2271560
  • Korean J Orthod.
  • 1995 Feb;25(1):43-54.
This study was conducted to examine the metal release of TiN-plated stainless steel orthodontic appliances by constructing the simulated orthodontic appliances equivalent to maxillary half arch, by dividing into TiN-plated...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The frictional resistance of tin ion-plated Co-Cr orthodontic wire

Lee HK, Kwon OW, Kim KH

  • KMID: 1923876
  • Korean J Orthod.
  • 1998 Feb;28(1):123-133.
The effectiveness of TiN ion-plating was examined with TiN ion-plated Co-Cr wires(016", 016"X.022") on three different types of bracket(TiN ion-plated metal bracket, ceramic bracket and plastic bracket). Maximum static frictional...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Discoloration and corrosion resistance of Tin-coated orthodontic appliances produced by Ion-plating method

Kim JH, Kwon OW, Choi YY

  • KMID: 2271548
  • Korean J Orthod.
  • 1993 Sep;23(3):327-340.
The purpose of this study was to estimate the possibility of practical application of TiN ion-plating method on orthodontic appliances. TiN was coated on the surface of orthodontic stainless steel...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of TiN coating of abutment screw on detorque force

Kim HJ, Choe HC, Chung CH

  • KMID: 2195655
  • J Korean Acad Prosthodont.
  • 2007 Jun;45(3):329-338.
PURPOSE: The aim of this study is to evaluate the effect of TiN coating of abutment screw on the unscrewing torque. MATERIAL AND METHODS: Titanium and Gold-Tite abutment screws were classified...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Psychoanalytic Understanding of The Novel, ‘The Tin Drum’

Kang H

The purpose of this paper is to make a psychoanalytic investigation on the novel, ‘The tin drum’ which was written by the Gunter Grass. For this purpose, I made a...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Overview of IgG4-Related Tubulointerstitial Nephritis and Its Mimickers

Jeong HJ, Shin SJ, Lim BJ

Tubulointerstitial nephritis (TIN) is the most common form of renal involvement in IgG4-related disease. It is characterized by a dominant infiltrate of IgG4-positive plasma cells in the interstitium and storiform...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of the frictional resistance between non-ion plated and Tin ion plated to the orthodontic appliance

Jang SH, Kwon OW, Kim KH

  • KMID: 2271360
  • Korean J Orthod.
  • 1993 Dec;23(4):671-691.
To estimate the possibility in the application of TiN ion-plating to the orthodontic appliance, this study investigated frictional force and frictional coefficient between non-ionplated and TiN ion-plated to the orthodontic...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Abrasion of abutment screw coated with TiN

Jung SW, Son MK, Chung CH, Kim HJ

STATEMENT OF PROBLEM: Screw loosening has been a common complication and still reported frequently. PURPOSE: The purpose of this study was to evaluate abrasion of the implant fixture and TiN...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Improvement effects of electrochemical stability of magnetic materials for prosthetic dentistry

Kwack JH, Oh SH, Choe HC, Chung CH

  • KMID: 2000644
  • J Korean Acad Prosthodont.
  • 2006 Oct;44(5):628-641.
STATEMENT OF PROBLEM: Dental magnetic materials have been applied to removable prosthetic appliances, maxillofacial prostheses, obturator and dental implant but they still have some problems such as low corrosion resistance...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Detorque force of TiN-coated abutment screw with various coating thickness after repeated closing and opening

Kim HS, Kim HJ, Chung CH

  • KMID: 2195632
  • J Korean Acad Prosthodont.
  • 2007 Dec;45(6):769-779.
STATEMENT OF PROBLEM: When TiN coating is applied to the abutment screw, occurrence of greater preload and prevention of the screw loosening could be expected due to decrease of frictional...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A case of treatment-induced neuropathy in an adolescent with type 1 diabetes

Varadharaju N, Jeevarathnam D, Rajan M, Ponnurangam Nagarajan V, James S

Treatment-induced neuropathy (TIN) in diabetes is an acute and painful yet completely reversible small fiber neuropathy precipitated by a rapid improvement in glycemic control. TIN is rare in children. A...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Surface change and fit of TiN-coated abutment screw after repeated closing and opening

Kim JN, Chung CH, Kim HJ

  • KMID: 2195702
  • J Korean Acad Prosthodont.
  • 2007 Feb;45(1):119-130.
STATEMENT OF PROBLEM: A few dry lubricants were applied to abutment screws for the improvement of joint stability. PURPOSE: The purpose of this study was to evaluate the surface change...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Analytical Interpretation of Drama and Cinema 'Cat on a Hot Tin Roof' Based on The Original Play by Tennessee Williams

Kim E

  • KMID: 1430641
  • Psychoanalysis.
  • 2013 Apr;24(1):39-49.
Four different version of "Cat on a Hot Tin Roof" (three stage drama and one movie) based on original play by Tennessee Williams are analyzed. Two versions ("Cat, No. 1"...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A study on mechanical properties of TiN, ZrN and WC coated film on the titanium alloy surface

Oh DJ, Kim HJ, Chung CH

  • KMID: 2000654
  • J Korean Acad Prosthodont.
  • 2006 Dec;44(6):740-750.
STATEMENT OF PROBLEMS: In an attempt to reduce screw loosening, dry lubricant coatings such as pure gold or tefron have been applied to the abutment screw. However, under repeated tightening...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A STUDY OF ION BEAM ASSISTED DEPOSITION(IBAD) OF TiN ON Ni-Cr Be ALLOY FOR SURFACE CHARACTERISTIC

Choi SY, Lee SH, Chang IT, Yang JH, Chung HY

  • KMID: 1907071
  • J Korean Acad Prosthodont.
  • 1999 Apr;37(2):212-234.
Dental restorative materials must have the physical properties to withstand wear and corrosion. Base metal alloys possess better mechanical properties and lower price than the gold alloys. For these reason...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Mechanical properties of tin coated film with various coating thickness on titanium alloy

Lee JY, Oh DJ, Kim HJ, Chung CH

  • KMID: 2000562
  • J Korean Acad Prosthodont.
  • 2007 Oct;45(5):675-686.
STATEMENT OF PROBLEM: Titanium nitride(TiN) coatings are the most general and popular coating method and used to improve the properties of metallic surface for industrial PURPOSEs. When TiN coating applied...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The physical properties of tin ion-plated Co-Cr (elgiloy) orthodontic wires

Kim JM, Kwon OW, Kim KH

  • KMID: 2271787
  • Korean J Orthod.
  • 1998 Jun;28(3):371-377.
To estimate the possibility of clinical application of TiN ion-plated Elgiloy(Co-Cr wire), measurements of tensile strength and hardness were made on the four tempers on each of the manufactured Elgiloy,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effects of surface coating on the screw release of dental implant screw

Koo CI, Chung CH, Choe HC

  • KMID: 2195775
  • J Korean Acad Prosthodont.
  • 2004 Apr;42(2):210-225.
STATEMENT OF PROBLEM: Implant screw loosening has been remained problem in restorative practices. Surface treatment of screw plays a role of preventing screw from loosening in implant screw mechanism. PURPOSE:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Size Control of 99mTc-tin Colloid Using PVP and Buffer Solution for Sentinel Lymph Node Detection

Kim EM, Lim ST, Sohn MH, Jeong HJ

Colloidal particle size is an important characteristic that allows mapping sentinel nodes in lymphoscintigraphy. This investigation aimed to introduce different ways of making a 99mTc-tin colloid with a size of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr