Reliability of implant stability measuring devices depending on various clinical conditions: an in vitro study

Lee HN, Kim MS, Lee JY, Zihan X, Ryu JJ, Shim JS

PURPOSE. The aim of this study was to evaluate the reliability of implant stability measuring devices depending on the location of the implant and the position of the patient. MATERIALS...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of abutment types and resin cements on the esthetics of implant-supported restorations

Çeken A, Kılınç H, Turgut S

PURPOSE. The aim of the study was to evaluate the optical properties of new generation (3Y-TZP) monolithic zirconia (MZ) with different abutment types and resin cement shades. MATERIALS AND METHODS....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems

Bae EB, Cho WT, Park DH, Hwang SH, Lee SH, Yun MJ, Jeong CM, Huh JB

PURPOSE. This study aims to clinically compare the fitness and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems. MATERIALS AND METHODS. Total of 40 patients were enrolled...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of the type of resin cement on the fracture resistance of chairside CAD-CAM materials after aging

Rizzatto LV, Meneghetti D, Domênico MD, Facenda JC, Weber KR, Corazza PH, Borba M

PURPOSE. The study objective was to evaluate the influence of the type of resin cement on the flexural strength and load to fracture of two chairside CADCAM materials after aging....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of internal structures on the accuracy of 3D printed full-arch dentition preparation models in different printing systems

Ma T, Peng T, Lin Y, Zhang M, Ren G

PURPOSE. The objective of this study was to investigate how internal structures influence the overall and marginal accuracy of full arch preparations fabricated through additive manufacturing in different printing systems....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of implant diameter and cantilever length on the marginal bone height changes and stability of implants supporting screw retained prostheses: A randomized double blinded control trial

Khorshid HE, Issa NO, Ekram AM

PURPOSE. This randomized controlled trial aimed to evaluate the effect of implants’ two different diameters and cantilever lengths on the marginal bone loss and stability of mplants supporting maxillary prostheses....