Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

PUBLICATION DATE

52 results
Display

Effect of changing the kilovoltage peak on radiographic caries assessment in digital and conventional radiography

Zayet MK, Helaly YR, Eiid SB

PURPOSE: This study aimed to investigate the effect of changing the kilovoltage peak (kVp) on the radiographic assessment of dental caries. MATERIALS AND METHODS: Seventy-five extracted posterior teeth with proximal caries...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Direct digital radiography versus conventional radiography for estimation of canal length in curved canals

Mohtavipour ST, Dalili Z, Azar NG

PURPOSE: The purpose of this study was to compare the conventional and digital radiography in the estimation of working length in mandibular molars. MATERIALS AND METHODS: Sixty molar teeth were selected...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Absorbed and effective dose for periapical radiography using portable and wall type dental X-ray machines

Han WJ

PURPOSE: The purpose of this study was to measure the absorbed dose and to calculate the effective dose for one periapical radiography using the portable and wall type dental X-ray...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Absorbed and effective dose in direct and indirect digital panoramic radiography

Lee GS, Kim JS, Kim JD

  • KMID: 2270926
  • Korean J Oral Maxillofac Radiol.
  • 2010 Mar;40(1):9-14.
PURPOSE: We evaluated the absorbed doses to the organs and calculated the effective doses when using the digital panoramic radiography. MATERIALS AND METHODS: The absorbed dose averages in major organs of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Physical principles of digital radiographic imaging system

Choi JW, Yi WJ

  • KMID: 2074831
  • Korean J Oral Maxillofac Radiol.
  • 2010 Dec;40(4):155-158.
Digital radiographic systems allow the implementation of a fully digital picture archiving and communication system (PACS), and provide the greater dynamic range of digital detectors with possible reduction of X-ray...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of digital noise reduction on the accuracy of endodontic file length determination

Mehdizadeh M, Khademi AA, Shokraneh , Farhadi N

PURPOSE: The aim of the present study was to evaluate the measurement accuracy of endodontic file length on periapical digital radiography after application of noise reduction digital enhancement. MATERIALS AND METHODS:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Image enhancement of digital periapical radiographs according to diagnostic tasks

Choi JW, Han WJ, Kim EK

PURPOSE: This study was performed to investigate the effect of image enhancement of periapical radiographs according to the diagnostic task. MATERIALS AND METHODS: Eighty digital intraoral radiographs were obtained from patients...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of digital models generated from three-dimensional optical scanner and cone beam computed tomography

Kwon HJ, Kim KK, Yi WJ

PURPOSE: The objective of this study was to compare the accuracy of digital models from 3 dimentional (3D) optical scanner and cone beam computed tomography (CBCT). MATERIALS AND METHODS: We obtained...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effective dose from direct and indirect digital panoramic units

Lee GS, Kim JS, Seo YS, Kim JD

PURPOSE: This study aimed to provide comparative measurements of the effective dose from direct and indirect digital panoramic units according to phantoms and exposure parameters. MATERIALS AND METHODS: Dose measurements were...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A study of the mandibular canal in digital panoramic radiographic images of a selected Korean population

Kim JD, Kim JS

  • KMID: 2270889
  • Korean J Oral Maxillofac Radiol.
  • 2007 Mar;37(1):9-14.
PURPOSE: To determine the more valuable information to detect the mandibular canal and the mental foramen in panoramic radiographs of a selected Korean population for the implant. MATERIALS AND METHODS:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
More frequent detection of calcified carotid atherosclerotic plaques and mineralized laryngeal cartilages on digital than on film-based panoramic radiographs

de-Azevedo-Vaz SL, Machado JV, Pereira TC, Freitas DQ

PURPOSE: To determine whether calcified carotid atherosclerotic plaques (CCAPs) and mineralized laryngeal cartilages (MLCs) were more frequently detected on digital or film-based panoramic radiographs. The clinical relevance of this question...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A comparison of film and 3 digital imaging systems for natural dental caries detection: CCD, CMOS, PSP and film

Han WJ

  • KMID: 2270864
  • Korean J Oral Maxillofac Radiol.
  • 2004 Mar;34(1):1-6.
PURPOSE: To evaluate the diagnostic accuracy of occlusal and proximal caries detection using CCD, CMOS, PSP and film system. MATERIALS AND METHODS: 32 occlusal and 30 proximal tooth surfaces were...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A comparative study on the accuracy of digital subtraction radiography according to the aquisition methods of reconstructed images

Huh YJ, Jeon IS, Heo MS, Lee SS, Choi SC, Park TW, Kim JD

  • KMID: 1924073
  • Korean J Oral Maxillofac Radiol.
  • 2002 Jun;32(2):107-111.
PURPOSE: To compare the accuracy of digital subtraction images acquired by two different methods different in positioning four reference points for geometrical standardization. MATERIALS AND METHODS: A total of 36...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A comparative study of cone-beam computed tomography and digital periapical radiography in detecting mandibular molars root perforations

Haghanifar S, Moudi E, Mesgarani , Bijani A, Abbaszadeh N

PURPOSE: The aim of this in vitro study was to determine the sensitivity and specificity of cone-beam computed tomography (CBCT) and digital periapical radiography in the detection of mesial root...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The reduction methods of operator's radiation dose for portable dental X-ray machines

Cho JY, Han WJ

OBJECTIVES: This study was aimed to investigate the methods to reduce operator's radiation dose when taking intraoral radiographs with portable dental X-ray machines. MATERIALS AND METHODS: Two kinds of portable dental...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
How does duration of curing affect the radiopacity of dental materials?

Poorsattar Bejeh Mir A, Poorsattar Bejeh Mir M

PURPOSE: Clinicians commonly encounter cases in which it is difficult to determine whether adjacent radiopacities are normal or pathologic. The ideal radiopacity of composite resin is equal to or higher...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The efficacy of the reverse contrast mode in digital radiography for the detection of proximal dentinal caries

Miri S, Mehralizadeh S, Sadri D, Motamedi M, Soltani P

PURPOSE: This study evaluated the diagnostic accuracy of the reverse contrast mode in intraoral digital radiography for the detection of proximal dentinal caries, in comparison with the original digital radiographs. MATERIALS...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Study on the Diagnostic Detection Ability of the Artificial Proximal Caries by Digora(R)

Oh KR, Choi EH, Kim JD

  • KMID: 1537419
  • J Korean Acad Oral Maxillofac Radiol.
  • 1998 Aug;28(2):415-433.
Digora system is an intraoral indirect digital radiography system utilizing storage phosphor image plate. It has wide dynamic range which allows it to decrease the patient's exposure time and may...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Accuracy of digital periapical radiography and cone-beam computed tomography in detecting external root resorption

Creanga AG, Geha H, Sankar V, Teixeira F, McMahan CA, Noujeim M

PURPOSE: The purpose of this study was to evaluate and compare the efficacy of cone-beam computed tomography (CBCT) and digital intraoral radiography in diagnosing simulated small external root resorption cavities. MATERIALS...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Detection of peri-implant bone defects using cone-beam computed tomography and digital periapical radiography with parallel and oblique projection

Vadiati Saberi B, Khosravifard N, Ghandari F, Hadinezhad A

PURPOSE: To compare the diagnostic accuracy of cone-beam computed tomography (CBCT) with that of parallel (PPA) and oblique projected periapical (OPA) radiography for the detection of different types of peri-implant...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr