Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

66 results
Display

Design and Realization of Integrated Management System for Data Interoperability between Point-of-Care Testing Equipment and Hospital Information System

Park KS, Heo H, Choi YK

OBJECTIVES: The purpose of this study was to design an integrated data management system based on the POCT1-A2, LIS2-A, LIS2-A2, and HL7 standard to ensure data interoperability between mobile equipment,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Spontaneous elbow hemarthrosis identified by point-of-care ultrasound

Mackenzie , McCorvey S

Traumatic or spontaneous hemarthroses are an important cause of joint effusions, and can complicate innate or acquired coagulopathies. The elbow is an unusual location for a spontaneous hemarthrosis; we describe...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Pediatric lung ultrasound: its role in the perioperative period

Song IK

There have been a number of recent advancements in the field of point-of-care ultrasound, including lung ultrasound for adult and pediatric populations. Evidence-based guidelines on the use of point-of-care lung...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Point-of-Care Diagnostics for Infectious Diseases: Present and Future

Kim SH, Shin JH

No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Scenario-Based Assessment of User Needs for Point-of-Care Robots

Lee HS, Kim J

OBJECTIVES: This study aimed to derive specific user requirements and barriers in a real medical environment to define the essential elements and functions of two types of point-of-care (POC) robot:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of the i-Smart 30 Point-of-Care Analyzer for Use in Clinical Laboratory Settings

Seok Y, Lee W, Yoon S, Won Y, Kwon OH

  • KMID: 1848729
  • J Lab Med Qual Assur.
  • 2011 Jun;33(1):25-30.
BACKGROUND: The i-Smart 30 point-of-care (POC) analyzer (i-SENS, Korea) is a compact and portable system used for the analysis of electrolytes (sodium, potassium, chloride) and hematocrit in whole blood samples....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Dural sinus thrombosis identified by point-of-care ultrasound

Director L, Mackenzie

Dural sinus thrombosis (DST), or cerebral venous thrombosis, is an uncommon cause of stroke. It has a variable presentation, and the symptoms and signs can be non-specific. The diagnosis of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Case of Warfarin-Induced Bleeding in a Patient with CYP2C9 and VKORC1 Gene Polymorphism, Detected by a Point-of-Care Gene Test Device

Kim BS, Lee DH, Park HK, Kim M, Kim SH, Kim KH, Kim MH

  • KMID: 2267834
  • Korean J Med.
  • 2013 Jul;85(1):87-91.
A 69-year-old female Korean patient was initially prescribed warfarin for the prevention of systemic thromboembolism due to atrial fibrillation. One month later, multiple bruises and subcutaneous hematomas were evident, and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Installation of Network-Connected Point-of-Care Blood Glucose Meters

Oh SH, Jeong TD, Lee W, Chun S, Min WK

  • KMID: 2200496
  • J Lab Med Qual Assur.
  • 2013 Dec;35(2):138-142.
Point-of-care (POC) testing is desirable because of both the ease with which it can be administered and its short turnaround time. However, because standard POC devices cannot transmit test results...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Report on the External Quality Assessment Scheme for Blood Gas (Central Laboratory and Point-of-Care Testing) and Glucose (Point-of-Care Testing) Analysis in Korea (2016–2017)

Lim J, Chung HJ, Jeon BR, Kwon GC

In the 2016 and 2017 programs for blood gas analysis (BGA) in central laboratory and by point-of-care testing (POCT), and glucose analysis by POCT, external quality assessment of 9, 3,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of i-STAT CHEM8+ Point-of-Care Chemistry Analyzer

Kim DK, Shin H, Kim B, Jeong SH, Lim JB

BACKGROUND: We evaluated the analytical performance of the Abbott i-STAT CHEM8+, a point-of-care testing system that measures 8 basic chemical analytes, namely, sodium, potassium, chloride, total carbon dioxide, BUN, creatinine,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of Point-of-Care Testing for C-Reactive Protein in Forensic Medicine

Na JY, Park JT

BACKGROUND: C-reactive protein (CRP) is an acute-phase protein whose level increases in response to tissue injury, infection, or other inflammation. It is used in clinical and forensic settings. Point-of-care (POC)...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical Usefulness of Point-of-care Test Chemistry Analyzer in Neonatal Intensive Care Unit

Jang YU, Kim SN, Cho HJ, Sun YH, Shim SY, Son DW, Park PW

PURPOSE: Point-of-care tests (POCTs) have the potential to significantly influence management of neonates. The aim of this study was to assess the clinical usefulness of the POCT chemistry analyzer in...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of Cobas b 101 HbA1c Analyzer Performance for Point-of-Care Testing

Yu HJ, Lim S, Kwon MJ, Woo HY, Park H

BACKGROUND: The use of point-of-care (POC) devices for evaluating HbA1c is increasing; accordingly, comparisons between these devices and central laboratory methods are important. In the present study, we evaluated the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Point-of-care ultrasound may reduce emergency department length of stay in children with nonspecific manifestations of intussusception

Han SM, Kim JH, Lee JS

PURPOSE: To investigate whether performance of point-of-care ultrasound (POCUS) can reduce emergency department length of stay (EDLOS) for children with nonspecific manifestations of intussusception (NMI), defined as 2 or less...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of the i-STAT Point-of-Care Analyser

Oh Y, Koo SH, Kwon GC

BACKGROUND: Point-of-care testing (POCT) is designed to be used near the site where the clinical care is being delivered. The demand for POCT in the medical field is expanding significantly,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Transthoracic echocardiography probe in an anesthesiologist's hand: utility in the operating room

Hwang GS

With increased availability and feasibility of bedside sonography, point-of-care ultrasonography is a rapidly developing field in many fields of emergency and intensive care medicine. Although anesthesiologists frequently encounter severe hypotension...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The influence of the decision making time by using point-of-care creatinine in patients with acute abdomen

Choi Y, Cho S, Ahn H, Min J, Jeong W, Ryu S, Oh S, Kim S, You Y, Lee J, Park J, Yoo I, Cho Y

OBJECTIVE: Radio-contrast abdomino-pelvic computed tomography (APCT) is considered the gold standard diagnostic tool for an acute abdomen in the emergency department. On the other hand, APCT has a risk of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Performance Evaluation of the LABGEO PT10 Point-of-care Chemistry Analyzer

Jeong TD, Lee W, Chun S, Min WK

  • KMID: 2200487
  • J Lab Med Qual Assur.
  • 2013 Dec;35(2):70-80.
BACKGROUND: The Samsung LABGEO PT10 (Samsung Electronics, Korea) has been developed as a point-of-care testing (POCT) chemistry analyzer. We evaluated the performance of the Samsung LABGEO PT Biochemistry Test 15...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Performance Evaluation of the Point-of-Care Cardiac Troponin T Assay

Kim YH, Jeong TD, Hong KS

BACKGROUND: The point-of-care (POC) troponin T assay has been used in various clinical settings. Recently, a POC troponin T assay with an extended measurable range (40 ng/L-2,000 ng/L) was introduced....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr