Skip Navigation
Skip to contents
Filter

ARTICLE TYPE

PUBLICATION DATE

13 results
Display

Protocols of Myocardial Perfusion SPECT

Kim SM

  • KMID: 1926557
  • Korean J Nucl Med.
  • 2005 Apr;39(2):82-86.
In myocardial perfusion scintigraphy, the results of this evalution now confront the practitioner of nuclear medicine with methodologic options. Most nuclear cardiologic studies are performed using thallium-201, Tc-99m sestamibi and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Assessment of Ventricular Function Using Gated Blood Pool Scan and Gated Blood Pool SPECT

Park SG

  • KMID: 1926560
  • Korean J Nucl Med.
  • 2005 Apr;39(2):100-106.
Non-invasive evaluation of cardiac function by nuclear medicine technologies are one of the major contribution of nuclear medicine. Gated cardiac blood pool scan was once a novel and robust technique...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Tracking of Stem Cells for Treatment in Cardiovascular Disease

Kang WJ

  • KMID: 1926567
  • Korean J Nucl Med.
  • 2005 Apr;39(2):146-149.
Various stem cells or progenitor cells are being used to treat cardiovascular disease. In ischemic heart disease, stem cell therapy is expected to regenerate damaged myocardium. To evaluate effects of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Radiopharmaceuticals of Cardiac SPECT Imaging

Chung YA

  • KMID: 1926555
  • Korean J Nucl Med.
  • 2005 Apr;39(2):69-74.
Ever since it was first introduced as a method of scintigraphically measuring regional myocardial perfusion, myocardial perfusion study has been widely used in patients diagnosed or suspected with coronary artery...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Current Trends and Future Development in Pharmacologic Stress Testing

Bae JH, Lee J

  • KMID: 1926561
  • Korean J Nucl Med.
  • 2005 Apr;39(2):107-113.
Pharmacologic stress testing for myocardial perfusion imaging is a widely used noninvasive method for the evaluation of known or suspected coronary artery disease. The use of exercise for cardiac stress...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Quantification of Myocardial Perfusion and Function Using SPECT and PET

Lee JS

  • KMID: 1926556
  • Korean J Nucl Med.
  • 2005 Apr;39(2):75-81.
Myocardial perfusion and function can be quantified using SPECT and PET. There was controversy over the usefulness of the correction techniques for physical artifacts, such as photon attenuation and scatter,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
PET and PET/CT in Clinical Cardiology

Won KS

  • KMID: 1926564
  • Korean J Nucl Med.
  • 2005 Apr;39(2):124-132.
Cardiac PET emerged as a powerful tool that allowed in vivo quantification of physiologic processes including myocardial perfusion and metabolism, as well as neuronal and receptor function for more than...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of Myocardial Blood Flow and Coronary Flow Reserve Using Positron Emission Tomography

Lee BI, Bom HS

  • KMID: 1926563
  • Korean J Nucl Med.
  • 2005 Apr;39(2):118-123.
Positron emission tomography (PET) serves as a gold standard for noninvasive in vivo measurement of myocardial blood flow (MBF) and coronary flow reserve (CFR). CFR can be defined as the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Imaging Hypoxic Myocardium

Bae SK

  • KMID: 1926566
  • Korean J Nucl Med.
  • 2005 Apr;39(2):141-145.
Hypoxia (decreased tissue oxygen tension) is a component of many diseases such as tumors, cerebrovascular diseases and ischemic heart diseases. Although hypoxia can be secondary to a low inspired pO2...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Assessment of Myocardial Viability Using PET

Yoon SN

  • KMID: 1926565
  • Korean J Nucl Med.
  • 2005 Apr;39(2):133-140.
The potential for recovery of left ventricular dysfunction after myocardial revascularization represents a practical clinical definition for myocardial viability. The evaluation of viable myocardium in patients with severe global left...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Accuracy of Ventricular Volume and Ejection Fraction Measured by Gated Tl-201 Perfusion Single Photon Emission Tomography

Pai M, Moon DH

  • KMID: 1926559
  • Korean J Nucl Med.
  • 2005 Apr;39(2):94-99.
Electrocardiogram-gated single photon emission computed tomography (SPECT) provides valuable information in the assessment of both myocardial perfusion and ventricular function. Tl-201 is a suboptimal isotope for gating. Tl-201 images are...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Usefulness of Myocardial Perfusion SPECT after Percutaneous Coronary Intervention (PCI)

Lee JJ, Lee DS

  • KMID: 1926562
  • Korean J Nucl Med.
  • 2005 Apr;39(2):114-117.
As the indication of percutaneous coronary intervention (PCI) has expanded to the more difficult and complicated cases, frequent restenosis is still expected after PCI. According to AHA/ACC guideline of the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Updates in the Management of Coronary Artery Disease

Yang DH, Chae SC

  • KMID: 1926558
  • Korean J Nucl Med.
  • 2005 Apr;39(2):87-93.
Coronary artery disease (CAD) has been increasing during the last decade and is the one of major causes of death. The management of patients with coronary artery disease has evolved...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr