Skip Navigation
Skip to contents
Filter

ARTICLE TYPE

PUBLICATION DATE

8 results
Display

Radiological Emergencies and the Medical Physicist

Hendee W

  • KMID: 2307123
  • Korean J Med Phys.
  • 2011 Mar;22(1):1-2.
No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Correction Method of Dose to Attenuation Rate of Transmitting Photon Beam Through Couch Top for Radiosurgery Using Novalis

Kim SJ, Shin HS, Ko SY, Park H, Kim JY, Lee BM, Yea JW, Kim SK

  • KMID: 2307125
  • Korean J Med Phys.
  • 2011 Mar;22(1):12-17.
This study has its own goal to deliver the accurate dose on the target volume by calculating and modifying the attenuation rate of photon beam transmitting the couch top with...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
3-Dimensional Verification Technique for Target Point Error

Lee KN, Lee DJ, Suh TS

  • KMID: 2307128
  • Korean J Med Phys.
  • 2011 Mar;22(1):35-41.
For overall system test, hidden-target test have been used using film which leads to inherent analysis error. The purpose of our study is to quantify this error and to propose...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Feasibility Study of the Radiophotoluminescent Glass Dosimeter for High-energy Electron Beams

Son K, Jung H, Shin SH, Lee HH, Lee S, Kim MS, Ji YH, Kim KB

  • KMID: 2307130
  • Korean J Med Phys.
  • 2011 Mar;22(1):52-58.
Our goal is to assess the suitability of a glass dosimeter on detection of high-energy electron beams for clinical use, especially for radiation therapy. We examined the dosimetric characteristics of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Feasibility Study of Vertical Multileaf Collimator for Determination of Irradiation Size

Lee CY, Son K, Shin SH, Park S, Lee D, Jung H, Choi M, Oh WY, Kim KB, Yang GM, Ji YH

  • KMID: 2307124
  • Korean J Med Phys.
  • 2011 Mar;22(1):3-11.
The purpose of this study was to evaluate feasibility of Vertical Multileaf Collimator for determination of irradiation size using Vertical Multileaf Collimator and lead block to determine 4 different irradiation...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Neuro-Anatomical Evaluation of Human Suitability for Rural and Urban Environment by Using fMRI

Kim GW, Song JK, Jeong GW

  • KMID: 2307126
  • Korean J Med Phys.
  • 2011 Mar;22(1):18-27.
The purpose of this study was to identify different cerebral areas of the human brain associated with rural and urban picture stimulation using a 3.0 Tesla functional magnetic resonance imaging...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Enhancement of the Deformable Image Registration Accuracy Using Image Modification of MV CBCT

Kim MJ, Chang J, Park SH, Kim TH, Kang YN, Suh TS

  • KMID: 2307127
  • Korean J Med Phys.
  • 2011 Mar;22(1):28-34.
To perform the Adaptive Radiation Therapy (ART), a high degree of deformable registration accuracy is essential. The purpose of this study is to identify whether the change of MV CBCT...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Quantitative Assessment Technology of Small Animal Myocardial Infarction PET Image Using Gaussian Mixture Model

Woo SK, Lee YJ, Lee W, Kim MH, Park JA, Kim JS, Kim JG, Kang JH, Ji YH, Choi CW, Lim SM, Kim KM

  • KMID: 2307129
  • Korean J Med Phys.
  • 2011 Mar;22(1):42-51.
Nuclear medicine images (SPECT, PET) were widely used tool for assessment of myocardial viability and perfusion. However it had difficult to define accurate myocardial infarct region. The purpose of this...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr