Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

PUBLICATION DATE

18 results
Display

A Study on the Accuracy of the record base of the Complete Denture to the Master Cast according to Kinds of Resin and Polymerization Method

Choi HJ, Lim JH, Jo IH

  • KMID: 2136365
  • J Korean Acad Prosthodont.
  • 2000 Jun;38(3):310-320.
STATEMENT of THE PROBLEM: The record base in fabricating procedures of the complete denture, as a temporary form for reproducing denture base, is used to record upper and lower jaw...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Fabrication of complete dentures for a patient with odontogenic myxoma: A case report

Jeong DW, Kim HH, Bae JY

Odontogenic myxoma of the jaws is a rare benign odontogenic tumor. In this case, a 61-year-old male patient had a chief complaint about maxillary anterior gingival mass and excisional biopsy...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Accuracy comparison of buccal bite scans by five intra-oral scanners

Park JM, Jeon J, Heo SJ

PURPOSE: The purpose of this study was to investigate the accuracy of the interocclusal relationship between upper and lower teeth according to the buccal interocclusal record scan using various intraoral...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The effect of CR-CO discrepancy on cephalometric measurements in Class III malocclusion patients

Park YS, Kim JC, Hwang HS

  • KMID: 1923655
  • Korean J Orthod.
  • 1996 Jun;26(3):255-266.
The purpose of this study was to investigate if there were a significant difference between cephalometric measurements of mandibular position derived from a centric occlusion tracing compared to those of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Relationship between CO-CR discrepancy and facial skeletal type

Cho JY, Lee YJ, Park YG, Chung KR

  • KMID: 2271812
  • Korean J Orthod.
  • 1998 Oct;28(5):839-853.
The present study was performed to prove the relationship between CO-CR discrepancy and facial skeletal type. In this study, 242 subjects were randomly selected and devided into 9 groups(devided into...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A STUDY ON ACCUARACY AND DIMENSIONAL STABILITY ACCORDING TO IMPRESSION METHODS

Lee JY, Lim JH, Cho IH

  • KMID: 1907056
  • J Korean Acad Prosthodont.
  • 1999 Oct;37(5):567-580.
Accurate reproduction of intraoral tissue is essential in the fabrication of fixed prosthesis. This selection of impression material and method is very important. In this study, vinyl polysiloxane type impression...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The treatment of an edentulous patient with DENTCA(TM) CAD/CAM Denture

Park JH, Cho IH, Shin SY, Choi YS

Nowadays, CAD/CAM is broadly used in dentistry for inlays, crowns, implant abutments and its spectrum is expanding to complete dentures. Utilizing CAD/CAM to fabricate complete dentures is expected to decrease...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Accuracy of several implant bite registration techniques: an in-vitro pilot study

Park DH, Park JM, Choi JW, Kang ES, Bae EB, Jeon YC, Jeong CM, Yun MJ, Huh JB

PURPOSE: This study evaluated the accuracies of different bite registration techniques for implant-fixed prostheses using three dimensional file analysis. MATERIALS AND METHODS: Implant fixtures were placed on the mandibular right second...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Differences in opening and protrusive mandibular movements between Class I and II malocclusions in healthy adolescents

Tuncer BB, Ozogul B, Akkaya S

OBJECTIVE: The aim of the study was to compare the opening and protrusive mandibular movements between Class I and Class II malocclusions in healthy adolescents by clinical and axiographic evaluations. METHODS:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of mechanical and projective standardization in digital subtraction radiography

Choi BI, Cho BH, Nah KS

  • KMID: 1537335
  • J Korean Acad Oral Maxillofac Radiol.
  • 1998 Feb;28(1):215-224.
The following conclusions were obtained from the non-reconstructed and reconstructed subtraction images of the standard intraoral radiographs which were taken with paralleing technique with Rinn XCP only and with occlusal...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A comparison of subtracted images from dental subtraction programs

Han WJ

  • KMID: 1873559
  • Korean J Oral Maxillofac Radiol.
  • 2002 Sep;32(3):147-151.
PURPOSE: To compare the standard deviation of gray levels on digital subtracted images obtained by different dental subtraction programs. MATERIALS AND METHODS: Paired periapical films were taken at the lower premolar...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A STUDY ON MASTICATORY PERFORMANCE AND MUSCLE ACTIVITY IN REMOVABLE PARTIAL DENTURE WEARERS

paik J, Park NS

  • KMID: 2195358
  • J Korean Acad Prosthodont.
  • 1998 Feb;36(1):81-103.
The purpose of this study was to compare and evaluate the differences in masticatory performance, muscle activity, and patterns of occlusal contact between persons with natural dentition and removable partial...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
THE EFFECT OF SCREW HOLE SEALING METHOD ON ABUTMENT SCREW LOOSENING IN DENTAL IMPLANT

Lim JB, Yim SH, Cho IH

  • KMID: 2196095
  • J Korean Acad Prosthodont.
  • 1997 Dec;35(4):767-780.
One of the most common problems of implant prosthesis is the screw loosening of abutment screws. This brings on discomfort on mastication, inflammation in the peri-implant tissue due to poor...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A simple technique for impression taking of teeth and functionally generated paths

Yamamoto T, Sato Y, Watanabe H, Punj A, Abe M, Momoi Y, Ohkubo C

The objective of this case report is to introduce a simple technique for simultaneously taking a closed-mouth impression and functionally generated path (FGP) for a full coverage crown restoration. A...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Accuracy of five implant impression technique: effect of splinting materials and methods

Lee SJ, Cho SB

PURPOSE: The aim of this study was to evaluate the effect of dimensional stability of splinting material on the accuracy of master casts. MATERIALS AND METHODS: A stainless steel metal model...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A STUDY ON THE ACCURACY OF THE IMPRESSION BODY ACCORDING TO MATERIALS AND FORMS OF THE INDIVIDUAL TOOTH TRAY

Ryu DW, Lim JH, Cho IH

  • KMID: 2196024
  • J Korean Acad Prosthodont.
  • 2000 Apr;38(2):242-254.
Accurate impression is very important to achieve desirable prosthesis and there are many factors in taking a good impression. For example, types of impression material, types of impression tray, impression...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Nonsurgical management of pediatric condylar fractures: cases reports

Lee JK, Park IS, Noh YH, Kim DW, Kim WH, Lee HC

  • KMID: 1960601
  • J Korean Assoc Maxillofac Plast Reconstr Surg.
  • 2003 Jan;25(1):33-40.
Of all facial fractures in children, condylar fractures have the greatest propensity to produce a growth disturbance.The pediatric condylar fracture occurs very frequently in the mandible, but this injury is...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Integrating 3D facial scanning in a digital workflow to CAD/CAM design and fabricate complete dentures for immediate total mouth rehabilitation

Hassan B, Greven M, Wismeijer

PURPOSE: To integrate extra-oral facial scanning information with CAD/CAM complete dentures to immediately rehabilitate terminal dentition. MATERIALS AND METHODS: Ten patients with terminal dentition scheduled for total extraction and immediate denture...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr