Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

29 results
Display

Echocardiography in Transcatheter Aortic Valve Implantation and Mitral Valve Clip

Siegel RJ, Luo H

Transcatheter aortic valve implantation and transcatheter mitral valve repair (MitraClip) procedures have been performed worldwide. In this paper, we review the use of two-dimensional and three-dimensional transesophageal echo for guiding...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Artificial Heart Valve Replacement

Choi JB

  • KMID: 1893631
  • Hanyang Med Rev.
  • 2007 May;27(2):18-27.
Since the first valve replacement was performed by Albert Starr more than 4 decades ago, the operative technique has remained largely the same. Differences in surgical technique have more to...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Successful emergency transcatheter aortic valve implantation

Lee JH, Ji AY, Kim YJ, Song C, Jin MN, Kim SW, Hong MK, Hong GR

Despite the necessity of surgical aortic valve replacement, many patients with symptomatic severe aortic stenosis (AS) cannot undergo surgery because of their severe comorbidities. In these high-risk patients, percutaneous transcatheter...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Monitored anesthesia care with dexmedetomidine in transfemoral percutaneous trans-catheter aortic valve implantation: two cases report

Park HS, Kim KM, Joung KW, Choi IC, Sim JY

Percutaneous trans-catheter aortic valve implantation (TAVI) is recommended for inoperable patients with severe aortic stenosis at high risk for conventional aortic valve replacement. Originally, TAVI was mostly performed under general...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of Patient-Prosthesis Mismatch in Aortic Position on Late-Onset Tricuspid Regurgitation and Clinical Outcomes after Double Valve Replacement

Lee SH, Youn YN, Chang BC, Joo HC, Lee S, Yoo KJ

PURPOSE: Significant late-onset tricuspid regurgitation (TR) is unfortunately common after double valve replacement (DVR); however, its underlying factors remain undefined. We evaluated the effect of aortic patient-prosthesis mismatch (PPM) on...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Transcatheter Aortic Valve Implantation Using CoreValve by Transaortic Approach

Chun KH, Ko YG, Shim JY, Lee S, Chang BC, Shim JK, Kwak YR, Hong MK

INTRODUCTION: Transcatheter aortic valve implantation (TAVI) is now considered as an alternative treatment option for severe aortic stenosis (AS) patients who cannot undergo surgical aortic valve replacement (AVR). CASE REPORT: We...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Spectral analysis of heart valve sound for detection of prosthetic heart valve diseases

Kim SH, Lee HJ, Huh JM, Chang BC

The spectral analysis of heart valve sound is a noninvasive diagnostic method known to be useful in evaluating the state of the heart valve function. This may provide early detection...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Case of Early Valve Replacement for Haemophilus parainfluenzae Endocarditis Complicated with Acute Cerebral Infarctions

Kang MH, Lim KR, Kim TS, Kim SH, Kim GH, Oh WS, Yie K

Haemophilus parainfluenzae, one of the member of the HACEK group of gram-negative oropharyngeal species, is a rare cause of subacute native valve endocarditis. Infective endocarditis caused by H. parainfluenzae appears...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Early Clinical Experience with Sutureless Aortic Valve Replacement for Severe Aortic Stenosis

Kim DJ, Kim HH, Lee SY, Lee S, Chang BC

BACKGROUND: Sutureless aortic valve replacement (SU-AVR) has been developed as an alternative surgical treatment for patients with symptomatic severe aortic stenosis (AS). The aim of this study was to evaluate...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Aortic Valve Replacement after Previous Coronary Artery Bypass Grafting with Patent Internal Mammary Artery

Jin MN, Kim SW, Kim YJ, Kim HJ, Lee JH, Hong MK, Chang BC

With the aging population, more patients who have undergone previous coronary artery bypass grafting (CABG) are surviving long enough to require subsequent aortic valve replacement (AVR). Conventional redo AVR after...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Aneurysm of Sinus of Valsalva Dissecting Into the Interventricular Septum After Aortic Valve Replacement: Diagnosis by Echocardiography and Magnetic Resonance Imaging and Treatment With Surgical Sealant

Park KH, Shin DG, Son CW, Son JW, Jo HS, Yoon JC, Lee WJ, Lee SH, Hong GR, Park JS, Kim YJ, Choi JH, Lee DH

Aneurysm of the sinus of Valsalva that causes dissection of the interventricular septum is an extremely rare entity. In this report we describe a case of aneurysm of the sinus...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The First Successful Transapical Aortic Valve Implant in Korea

Jeong DS, Park PW, Choi MS, Sung K, Kim WS, Lee YT, Gwon HC, Choi SH, Park SJ, Lee SM

Transcatheter aortic valve implantation is an alternative to open heart surgery in high risk patients with severe aortic stenosis. High mortality and complications related to cardiopulmonary bypass for conventional open...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Surgical Treatment of Degenerative Mitral Valve Regurgitation in the Elderly: Comparison of Early and Long-Term Outcomes Using Propensity Score Matching Analysis

Lee JS, Kim KH, Choi JW, Hwang HY, Kim KB

BACKGROUND: It is unclear whether mitral valve (MV) repair for degenerative mitral regurgitation (MR) provides the same advantages in the elderly that it does in the general population. METHODS: From 1994...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Early Outcomes of Sutureless Aortic Valves

Hanedan MO, Mataracı , Yürük MA, Özer T, Sayar U, Arslan AK, Ziyrek U, Yücel M

BACKGROUND: In elderly high-risk surgical patients, sutureless aortic valve replacement (AVR) should be an alternative to standard AVR. The potential advantages of sutureless aortic prostheses include reducing cross-clamping and cardiopulmonary...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Prosthesis-Patient Mismatch after Mitral Valve Replacement: Comparison of Different Methods of Effective Orifice Area Calculation

Cho IJ, Hong GR, Lee SH, Lee S, Chang BC, Shim CY, Chang HJ, Ha JW, Chung N

PURPOSE: The incidence of prosthesis-patient mismatch (PPM) after mitral valve replacement (MVR) has been reported to vary. The purpose of the current study was to investigate incidence of PPM according...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The change of QRS duration after pulmonary valve replacement in patients with repaired tetralogy of Fallot and pulmonary regurgitation

Yun Y, Kim YH, Kwon JE

PURPOSE: This study aimed to analyze changes in QRS duration and cardiothoracic ratio (CTR) following pulmonary valve replacement (PVR) in patients with tetralogy of Fallot (TOF). METHODS: Children and adolescents who...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Aortic Valve Involvement in Behet's Disease. A Clinical Study of 9 Patients

Lee CW, Lee J, Lee WK, Lee CH, Suh CH, Song CH, Park YB, Lee SK, Won YS

  • KMID: 1758678
  • Korean J Intern Med.
  • 2002 Mar;17(1):51-56.
OBJECTIVES: To assess the clinical features, pathologic findings, postoperative results and the effects of immunosuppressive therapy in patients with Beh et's disease (BD). METHODS: We reviewed the postoperative course of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Successful Resection of a Giant Left Ventricular Pseudoaneurysm Developed Later after Mitral Valve Replacement

Min SK, Sir JJ, Nah JC, Kim YI

We present a case of successful surgical resection of a giant left ventricular (LV) pseudoaneurysm that developed 5 yr after mitral valve replacement (MVR). A 59-yr-old female was admitted with...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Measurement of Opening and Closing Angles of Aortic Valve Prostheses In Vivo Using Dual-Source Computed Tomography: Comparison with Those of Manufacturers' in 10 Different Types

Suh YJ, Kim YJ, Hong YJ, Lee HJ, Hur J, Im DJ, Kim YJ, Choi BW

OBJECTIVE: The aims of this study were to compare opening and closing angles of normally functioning mechanical aortic valves measured on dual-source computed tomography (CT) with the manufacturers' values and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Surgical Experience with Infective Endocarditis and Aortic Root Abscess

Lee S, Chang BC, Park HK

PURPOSE: This study was conducted to evaluate the surgical outcomes of active infective endocarditis with aortic root abscess formation. MATERIALS AND METHODS: Between February 1999 and June 2012, 49 patients underwent...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr