Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

50 results
Display

Value of Pulsed Doppler Echocardiography in the Diagnosis of Aortic Regurgitation

Jeong MH, Kim SK, Park SJ, Park JC, Kang JC, Park OK

In order to assess the sensitively and specificity of the pulsed Doppler echocardiography in the aortic regurgitation, 44 patients with valvular heart diseases were examined by pulsed Doppler echocardiography. Every...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Pulsed doppler echocardiographic analysis of pulmonary venous flow in congenital heart diseases with left-to-right shunt

Seol KH, Son CS, Lee JW, Kim SK, Tockgo YC

  • KMID: 1691744
  • J Korean Pediatr Soc.
  • 1991 Jul;34(7):934-939.
No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Study of left and right ventricular diastolic dysfunction in the hypertensive patients by pulsed doppler echocardiography

Kang DH, Shin GJ

  • KMID: 1698305
  • Korean J Med.
  • 1993 Sep;45(3):291-298.
No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Usefulness of the Doppler Echocardiography in Patient with Atrial Septal Defect: Detection of Shunt Flow and Measurement of Qp/Qs Ratio

Jun JG, Park JH, Ma IY

For the determination of the usefulness of the pulsed Doppler echocardiographic diagnosis of ASD. We evaluated 185 children with congenital heart disase by subxiphoid approach. ASD was diagnosed when abnormal...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Diagnosis of Patent Ductus Arteriosus by Pulsed Doppler Echocardiography; Sensitivity and Specificity

Ma IY, Jun JG, Hah JO, Kim DH, Rhi JL

  • KMID: 1676921
  • J Korean Pediatr Soc.
  • 1987 Mar;30(3):275-280.
No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Doppler Echocardiographic Measurement of Cardiac Output

Hong TJ, Ha CB, Shin YW, Shin YK

A noninvasive method for assessing cardiac output was evaluated by comparing it with thermodilution determinations in 25 patients who admitted to Pusan national university hospital from March, 1985 to December,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Effects of Captopril(Capril(R)) on Early Diastolic Time Intervals in Dilated Cardiomyopathy

Ku DH, Kim BS, Choi YS, Geong YC, Seong IH, Jeon ES, Park CH

Time intervals and indices of left ventricular diastolic filling were studied by M-mode and pulsed Doppler Echocardiography in 18 dilated cardiomyopathy patients. After one two hours captopril(capril(R)) 25mg medication. 1)Systolic...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Reconstruction of the Transmitral Flow Rate Curve with M-Mode,2-Dimensional and Doppler Echocardiography -Validation Study-

Kim DW, Park SW, Kim DK, Ryu KH, Oh BH, Park YB, Choi YS, Seo JD, Lee YW

To validate ventricular diastolic phase parameters of reconstructed transmitral flow rate curve by M-mode, 2-dimensional and pulsed Doppler Echocardiography, these parameters were compared with same parameters by left ventriculography. The...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of Abnormal Coronary Artery Flow in Anomalous Coronary Artery Connections by Pulsed and Color Doppler Echocardiography

Hong YM

  • KMID: 2335163
  • J Korean Pediatr Soc.
  • 1996 Jan;39(1):78-87.
PURPOSE: Anomalous connection of coronary artery can result in damage of myocardial perfusion, myocardial infarction, or congestive heart failure. Echocardiography has been used to demonstrate coronary artery anomalies such...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Prediction of Pulmonary Arterial Pressure by Pulsed Doppler Echocardiography

Chae JS, Kim CS, Kim JH, Choi KB, Hong SJ, Kim HJ

Noninvasive prediction of pulmonary arterial pressure is of paramount importance in heart disease. To estimate pulmonary arterial pressure, several echocardiographic techniques, including abnormal pulmonary valve motion, prolongation of RV preejection...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Determination of Pulmonary to Systemic Flow Ratio and Prediction of Pulmonary Arterial Pressure in Children by Pulsed Doppler Echocardiography

Sohn S, Hong CY

The purpose of this study is to evaluate pulsed Doppler echocardiographic method (PD) for the measurement of pulmonary to systemic flow ratio (QP/Qs) and pulmonary arterial pressure in children. We...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Noninvasive Estimation of Pulmonary Arterial Pressure by a Pulsed Doppler Echocardiography

Kim SK, Jeon ES, Kim YH, Oh BH, Park YB, Choi YS, Seo JD, Lee YW

Fifty nine patients who had been admitted to Seoul National University Hospital from April to October in 1986 were prospectively examined by a pulsed Doppler echocardiography on one day before...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Diagnosis of Ventricular Septal Defect by Pulsed Doppler Echocardiography

Jun JG, Son JS

This study was performed to assess the accuracy of pulsed Doppler echocardiographic(PDE) diagnosis of ventricular septal defect(VSD). 119 children with congenital heart disease, aged 9 months to 17 years, admitted...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Left Ventricular Diastolic Filling in Dilated Cardiomyopathy: Pulsed Doppler Echocardiographic Study

Kim KS, Kim YS, Choue CW, Kim MS, Song JS, Bae JH

Abnormal left ventricular diastolic properties have been reported in dilated cardiomyopathy (DC). Characteristics of transmitral flow were analysed in 37 patients with DC and 29 age matched normal subjects by...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Visualization of Coronary Arteries by Color-Coded Transesophageal Doppler Echocardiography

Chun SS, Yang CM, Chung WS, Paik SH, Chai JS, Kim JH, Choi KB, Hong SJ

The visualization of coronary arteries by transthoracic two-dimensional echocardiography has been used for over 10 years. In many cases, the imaging quality is too poor to allow an anatomic evaluation. During...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Variation of parameters according to cardiac cycle length, evaluated by TDI in children

Lee CH, Kim JK, Jin HS, Park KY, Kim BS, Han MK

PURPOSE: This study aimed to determine the variation in parameters according to cardiac cycle length (CL; time interval between the QRS peaks on ECG) in children by using the conventional...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Changes of Doppler Echocardiographic Findings After Mitral Valve Operation

Joo SJ, Hyon MS, Doh MH, Kim CH, Oh BH, Park YB, Choi YS, Seo JD, Lee YW

Pulsed Doppler echocardiography was performed before and five to fifteen days (mean, 9.3 days) after mitral valve surgery to evaluate the change of pulmonary arterial pressure in 80 patients (29...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Pulsed Doppler Echocardiographic Left Ventricular Inflow Velocity Patterns of Mitral Stenosis and Severity Grading

Yoon YG, Jeong MH, Kim SK, Park SJ, Yang SJ, Park JC, Kang JC, Park OK

42 patients with mitral stenosis(MS), diagnosed by M-mode, 2-D sector scan and pulsed Doppler echocardiography, were evaluated. Among them 28 patients were complicated with atrial fibrillation and one foruth was...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Dual Pulsed-Wave Doppler Tracing of Right Ventricular Inflow and Outflow: Single Cardiac Cycle Right Ventricular Tei Index and Evaluation of Right Ventricular Function

Choi JO, Choi JH, Lee HJ, Noh HJ, Huh J, Kang IS, Lee HJ, Lee SC, Kim DK, Park SW

BACKGROUND AND OBJECTIVES: The reliability and usefulness of the right ventricular (RV) Tei index (RTX) remains controversial because it has not been possible to simultaneously measure RV inflow and outflow....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Pulmonary Venous Flow Pattern by Transesophageal Echocardiography in Healthy Young Adults

Song YS, Choi KY, Kim KS, Kim YN, Kim KB

BACKGROUND: Although a number of indices of diastolic function based on transmitral flow have been proposed, no single factor seems to be adequate for seperating patients with normal from with...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr