Skip Navigation
Skip to contents
Filter

ARTICLE TYPE

PUBLICATION DATE

13 results
Display

Is Minimal Invasive Plate Osteosynthesis a Viable Treatment Option for 4-part Proximal Humerus Fractures?

Cho CH

No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Posterior Shoulder Instability in the Patients with Bilateral Congenital Absence of Long Head of Biceps Tendon: A Case Report

Yoon SH, Heo K, Yoo JS, Kim SJ, Seo JB

Rare cases of a congenital absence of the long head of the biceps tendon (LHBT) have been reported, and its incidence is unknown. In a literature review of the congenital...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Another Glenoid Measurements for Shoulder Surgery

Jeong YS, Yum JK, Lee JS

BACKGROUND: We analyzed the angle between the glenoid anterior surface and glenoid axis, the range of the glenoid apex and the location of the glenoid apex for assistance during shoulder...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comminuted Radial Head Fracture in All-arthroscopic Repair of Elbow Fracture-dislocation: Is Partial Excision of the Radial Head an Acceptable Treatment Option?

Yang HS, Kim JW, Lee SH, Yoo BM

BACKGROUND: In elbow fracture-dislocation, partial excision of the comminuted radial head fracture that is not amenable to fixation remains controversial considering the accompanying symptoms. This study was undertaken to evaluate...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Radiologic Comparison of Humeral Position according to the Implant Designs Following Reverse Shoulder Arthroplasty: Analysis between Medial Glenoid/Medial Humerus, Lateral Glenoid/Medial Humerus, and Medial Glenoid/Lateral Humerus Designs

Cho NS, Nam JH, Hong SJ, Kim TW, Lee MG, Ahn JT, Rhee YG

BACKGROUND: The currently available reverse shoulder arthroplasty (RSA) designs can be classified into medial glenoid/medial humerus (MGMH), lateral glenoid/medial humerus (LGMH), and medial glenoid/lateral humerus (MGLH) prosthesis designs. The purpose...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Minimally Invasive Percutaneous Plate Osteosynthesis via a Deltoidsplitting Approach with Strut Allograft for the Treatment of Displaced 3- or 4-part Proximal Humeral Fractures

Noh YM, Kim DR, Kim CH, Lee SY

BACKGROUND: This study introduces a surgical technique with good clinical outcome useful in the treatment of osteoporotic displaced 3- or 4-part proximal humeral fractures. METHODS: From May 2014 to February 2016,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Radiologic Comparison of Operative Treatment Using a Hook Plate versus a Distal Clavicle Locking Plate of Distal Clavicle Fracture

Yoon B, Kim JY, Lee JS, Jung HS

BACKGROUND: The purpose of this study was to compare the radiologic results of patients who underwent surgery with a hook plate and a locking plate in distal clavicle fractures. METHODS: Sixty...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Delayed Lateral Row Anchor Failure in Suture Bridge Rotator Cuff Repair: A Report of 3 Cases

Jeong JJ, Ji JH, Park SJ

Compared to single row repair, use of lateral row anchors in suture bridge rotator cuff repair enhances repair strength and increases footprint contact area. If a lateral knotless anchor (push-in...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Clinical and Anatomical Outcomes between Delaminated Rotator Cuff Tear and Single Layer Rotator Cuff Tear

Park JW, Moon SH, Lee JH

BACKGROUND: Delaminated rotator cuff tear is known to be a degenerative tear having a negative prognostic effect. This study undertook to compare the anatomical and clinical outcomes of delaminated tears...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Posterior Interosseous Nerve Palsy Caused by a Ganglion of the Arcade of Frohse

Lee SJ, Hyun YS, Baek SH, Seo JH, Kim HH

A 51-year-old male who is right-handed visited the outpatient for right fingers-drop. The patient's fingers, including thumb, were not extended on metacarpophalangeal joint. The active motion of the right wrist...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Normal Range of Humeral Head Positioning on the Glenoid on Magnetic Resonance Imaging: Validation through Comparison of Computed Tomography and Magnetic Resonance Imaging

Kim JH, Min YK

BACKGROUND: To determine the normal range of humeral head positioning on magnetic resonance imaging (MRI). METHODS: We selected normal subjects (64 patients; group A) to study the normal range of humeral...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Another Assessment of Fat Degeneration of Retracted Supraspinatus Muscle

Jeong YS, Yum JK, Park SY

BACKGROUND: The purpose of this study was to assess the relevance of preoperative magnetic resonance imaging (MRI) evaluation by occupation ratio (OR) at maximum diameter of supraspinatus muscle. METHODS: Patients from...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Case Series of Symptomatic Distal Biceps Tendinopathy

Lee JH, Kim KC, Lee JH, Ahn KB, Rhyou IH

BACKGROUND: The study of conservative and surgical treatment of distal biceps tendinopathy and associated biceps tendon partial rupture. METHODS: Twenty-one cases with distal biceps tendonitis and partial ruptures were studied who...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr