Korean J Orthod.  2024 May;54(3):153-159. 10.4041/kjod23.160.

Effect of three common hot beverages on the force decay of orthodontic elastomeric chain within a 28-day period: An in vitro study

Affiliations
  • 1Department of Orthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
  • 2Department of Biomaterials, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
  • 3Department of Epidemiology and Biostatistics, Tehran University of Medical Sciences, Tehran, Iran

Abstract


Objective
This study aimed to assess the effects of commonly consumed hot drinks on the force decay of orthodontic elastomeric chains.
Methods
This in vitro experimental study evaluated 375 pieces of elastomeric chains with six rings placed on a jig. Four rings were stretched by 23.5 mm corresponding to the approximate distance between the canine and the second premolar. Fifteen pieces served as reference samples at time zero, and 360 pieces were randomized into four groups: control, hot water, hot tea, and hot coffee. Each group was further divided into six subgroups (n = 15) according to the different exposure periods. The specimens in the experimental groups were exposed to the respective solutions at 65.5°C four times per day for 90 seconds at 5-second intervals. The control group was exposed to artificial saliva at 37°C. The force decay of the samples was measured at 1, 2, 7, 14, 21, and 28 days using a universal testing machine. Data were analyzed using repeated-measures analysis of variance.
Results
Maximum force decay occurred on day 1 in all groups. The minimum force was recorded in the control group, followed by the tea, coffee, and hot water groups on day 1. At the other time points, the minimum force was observed in the tea group, followed by the control, coffee, and hot water groups.
Conclusions
Patients can consume hot drinks without concern about any adverse effect on force decay of the orthodontic elastomeric chains.

Keyword

Elastomeric chain; Force decay; Hot beverages; Orthodontics

Figure

  • Figure 1 The jig holding 15 pieces of stretched chains.

  • Figure 2 Mean force (N) in the study groups at different time points. CI, confidence interval.


Reference

1. De Genova DC, McInnes-Ledoux P, Weinberg R, Shaye R. 1985; Force degradation of orthodontic elastomeric chains--a product comparison study. Am J Orthod. 87:377–84. https://doi.org/10.1016/0002-9416(85)90197-6. DOI: 10.1016/0002-9416(85)90197-6. PMID: 3857862.
2. Evans KS, Wood CM, Moffitt AH, Colgan JA, Holman JK, Marshall SD, et al. 2017; Sixteen-week analysis of unaltered elastomeric chain relating in-vitro force degradation with in-vivo extraction space tooth movement. Am J Orthod Dentofacial Orthop. 151:727–34. https://doi.org/10.1016/j.ajodo.2016.10.020. DOI: 10.1016/j.ajodo.2016.10.020. PMID: 28364896.
3. Oshagh M, Ajami S. 2010; A comparison of force decay: elastic chain or tie-back method? World J Orthod. 11:e45–51. https://pubmed.ncbi.nlm.nih.gov/21490987/. PMID: 21490987.
4. Halimi A, Benyahia H, Doukkali A, Azeroual MF, Zaoui F. 2012; A systematic review of force decay in orthodontic elastomeric power chains. Int Orthod. 10:223–40. https://doi.org/10.1016/j.ortho.2012.06.013. DOI: 10.1016/j.ortho.2012.06.013. PMID: 22906378.
5. Javanmardi Z, Salehi P. 2016; Effects of Orthokin, Sensikin and Persica mouth rinses on the force degradation of elastic chains and NiTi coil springs. J Dent Res Dent Clin Dent Prospects. 10:99–105. https://doi.org/10.15171/joddd.2016.016. DOI: 10.15171/joddd.2016.016. PMID: 27429726. PMCID: PMC4946005. PMID: 95b4eac0de044b1bb463eb414c1f959b.
6. Masoud AI, Tsay TP, BeGole E, Bedran-Russo AK. 2014; Force decay evaluation of thermoplastic and thermoset elastomeric chains: a mechanical design comparison. Angle Orthod. 84:1026–33. https://doi.org/10.2319/010814-28.1. DOI: 10.2319/010814-28.1. PMID: 24784844. PMCID: PMC8638502.
7. Behnaz M, Dalaie K, Hosseinpour S, Namvar F, Kazemi L. 2017; The effect of toothpastes with bleaching agents on the force decay of elastomeric orthodontic chains. Eur J Dent. 11:427–31. https://doi.org/10.4103/ejd.ejd_83_17. DOI: 10.4103/ejd.ejd_83_17. PMID: 29279666. PMCID: PMC5727725.
8. Menon VV, Madhavan S, Chacko T, Gopalakrishnan S, Jacob J, Parayancode A. 2019; Comparative assessment of force decay of the elastomeric chain with the use of various mouth rinses in simulated oral environment: an in vitro study. J Pharm Bioallied Sci. 11(Suppl 2):S269–73. https://doi.org/10.4103/JPBS.JPBS_9_19. DOI: 10.4103/JPBS.JPBS_9_19. PMID: 31198351. PMCID: PMC6555337. PMID: de4ac7aeacc64ca1944e68758045c9de.
9. Pithon MM, Rodrigues AC, Sousa EL, Santos LP, Soares Ndos S. 2013; Do mouthwashes with and without bleaching agents degrade the force of elastomeric chains? Angle Orthod. 83:712–7. https://doi.org/10.2319/081012-646.1. DOI: 10.2319/081012-646.1. PMID: 23311601. PMCID: PMC8754043.
10. Baty DL, Volz JE, von Fraunhofer JA. 1994; Force delivery properties of colored elastomeric modules. Am J Orthod Dentofacial Orthop. 106:40–6. https://doi.org/10.1016/S0889-5406(94)70019-2. DOI: 10.1016/S0889-5406(94)70019-2. PMID: 8017348.
11. Weissheimer A, Locks A, de Menezes LM, Borgatto AF, Derech CD. 2013; In vitro evaluation of force degradation of elastomeric chains used in orthodontics. Dental Press J Orthod. 18:55–62. https://doi.org/10.1590/s2176-94512013000100014. DOI: 10.1590/S2176-94512013000100014. PMID: 23876950.
12. Nachan R, Kalia A, Al-Shahrani I. 2015; Force degradation of orthodontic elastomeric chain due to commonly consumed liquids: an in vitro study. World J Dent. 6:31–8. https://doi.org/10.5005/jp-journals-10015-1309. DOI: 10.5005/jp-journals-10015-1309.
13. Kumar K, Shetty S, Krithika MJ, Cyriac B. 2014; Effect of commonly used beverage, soft drink, and mouthwash on force delivered by elastomeric chain: a comparative in vitro study. J Int Oral Health. 6:7–10. https://pubmed.ncbi.nlm.nih.gov/25083025/. PMID: 25083025. PMCID: PMC4109247.
14. Ramachandraiah S, Sridharan K, Nishad A, Manjusha KK, Abraham EA, Ramees MM. 2017; Force decay characteristics of commonly used elastomeric chains on exposure to various mouth rinses with different alcohol concentration: an in vitro study. J Contemp Dent Pract. 18:813–20. https://pubmed.ncbi.nlm.nih.gov/28874647/. DOI: 10.5005/jp-journals-10024-2132.
15. Teixeira L, Pereira Bdo R, Bortoly TG, Brancher JA, Tanaka OM, Guariza-Filho O. 2008; The environmental influence of Light Coke, phosphoric acid, and citric acid on elastomeric chains. J Contemp Dent Pract. 9:17–24. https://doi.org/10.5005/jcdp-9-7-17. DOI: 10.5005/jcdp-9-7-17. PMID: 18997912.
16. Oshagh M, Khajeh F, Heidari S, Torkan S, Fattahi HR. 2015; The effect of different environmental factors on force degradation of three common systems of orthodontic space closure. Dent Res J (Isfahan). 12:50–6. https://doi.org/10.4103/1735-3327.150331. DOI: 10.4103/1735-3327.150331. PMID: 25709675. PMCID: PMC4336972. PMID: 1ce2c94056f54876bb4d4c1995ae5f05.
17. Braga E, Souza G, Barretto P, Ferraz C, Pithon M. 2019; Experimental evaluation of strength degradation of orthodontic chain elastics immersed in hot beverages. J Indian Orthod Soc. 53:244–8. https://doi.org/10.1177/0301574219867540. DOI: 10.1177/0301574219867540.
18. Sulaiman TH, Eriwati YK, Indrani D. 2018; Effect of temperature on tensile force of orthodontics power chain in artificial saliva solution. J Phys Conf Ser. 1073:062006. https://doi.org/10.1088/1742-6596/1073/6/062006. DOI: 10.1088/1742-6596/1073/6/062006.
19. Kassir CA, Daou M, Abboud M. 2020; Comparison of the force decay over time of four different brands of elastomeric chains (elongated to 25mm grey/transparent and closed/open): an in-vitro study. Int Orthod. 18:538–45. https://doi.org/10.1016/j.ortho.2020.05.003. DOI: 10.1016/j.ortho.2020.05.003. PMID: 32536451.
20. Omidkhoda M, Rashed R, Khodarahmi N. 2015; Evaluation of the effects of three different mouthwashes on the force decay of orthodontic chains. Dent Res J (Isfahan). 12:348–52. https://doi.org/10.4103/1735-3327.161453. DOI: 10.4103/1735-3327.161453. PMID: 26288625. PMCID: PMC4533193. PMID: 3eb098a1223148e9969488d314d59ec0.
Full Text Links
  • KJOD
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr