J Dent Hyg Sci.  2023 Dec;23(4):343-350. 10.17135/jdhs.2023.23.4.343.

Bacterial Contamination of Digital Panoramic Dental X-Ray Equipment

Affiliations
  • 1Department of Dental Hygiene, Kyungpook National University, Sangju 37224, Korea
  • 2Department of Dental Hygiene, College of Health and Medical Health Sciences, Cheongju University, Cheongju 28503, Korea

Abstract

Background
Digital panoramic dental X-ray equipment (PDX) is frequently used by patients and dental workers for diagnosis and examination in dental institutions; however, infection control has not been properly implemented. Therefore, in this study, we aimed to systematically review the potential risk of cross-infection in the dental environment by investigating the contamination level of general aerobic bacteria and Staphylococcus aureus, which are important in hospital infections, in PDX areas that people mainly contact.
Methods
This survey was conducted from March to May 2023 and covered one general hospital, three dental hospitals, and nine dental clinics equipped with PDX. Bacteria samples were collected from the left-handle, right-handle, forehead support, and head side support as the patient’s contact areas, as well as the X-ray exposure switch and left-click mouse button as the dental hygienist’s contact areas of the PDX. The collected bacteria were spread on Petrifilm, and colonies formed after 48 hours of culture were counted.
Results
General aerobic bacteria and S. aureus were detected in all areas investigated. Significant differences in bacterial counts between different regions of the PDX were observed in both groups (p<0.001). The detection rates of general aerobic bacteria (p<0.001) and S. aureus (p<0.001) were significantly higher in the contact areas of patients than those of dental hygienists. A positive correlation was observed between the forehead and the temple region in terms of general aerobic bacteria and S. aureus detection (r=1) (p<0.01).
Conclusion
Taken together, the presence of many bacteria, including S. aureus, detected in PDX indicates that PDX has a potential cross-infection risk. Our results therefore highlight the need for the development of appropriate disinfection protocols for reusable medical devices such as PDX and periodic infection prevention training for hospital-related workers, including dental hygienists.

Keyword

Bacteria; Contamination; Dental radiography; Infection control; Panoramic