Gut Liver.  2023 Sep;17(5):806-813. 10.5009/gnl220437.

Efficacy Analysis of Suprapapillary versus Transpapillary Self-Expandable Metal Stents According to the Level of Obstruction in Malignant Extrahepatic Biliary Obstruction

Affiliations
  • 1Department of Internal Medicine, Pusan National University School of Medicine and Biomedical Research Institute, Pusan National University Hospital, Busan, Korea
  • 2Department of Internal Medicine, Soonchunhyang University Hospital Cheonan, Cheonan, Korea
  • 3Department of Internal Medicine, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
  • 4Digestive Disease Center, CHA Bundang Medical Center, CHA University, Seongnam, Korea
  • 5Department of Internal Medicine, Inha University Hospital, Inha University School of Medicine, Incheon, Korea

Abstract

Background/Aims
The use of a self-expandable metal stent (SEMS) is recommended for unresectable malignant biliary obstruction (MBO). Stent-related adverse events might differ according to the position of the stent through the ampulla of Vater (AOV). We retrospectively evaluated SEMS patency and adverse events according to the position of the SEMS.
Methods
In total, 280 patients who underwent endoscopic SEMS placement due to malignant distal biliary obstruction were analyzed retrospectively. Suprapapillary and transpapillary SEMS insertions were performed on 51 patients and 229 patients, respectively.
Results
Between the suprapapillary group (SPG) and transpapillary group (TPG), the stent patency period was not significantly different (median [95% confidence interval]: 107 days [82.3 to 131.7] vs 120 days [99.3 to 140.7], p=0.559). There was also no significant difference in the rate of adverse events. In subgroup analysis, the stent patency for an MBO located within 2 cm from the AOV was found to be significantly shorter than that for an MBO located more than 2 cm from the AOV in the SPG (64 days [0 to 160.4] vs 127 days [82.0 to 171.9], p<0.001) and TPG (87 days [52.5 to 121.5] vs 130 [97.0 to 162.9], p<0.001). Patients with an MBO located within 2 cm from the AOV in both groups had a higher percentage of duodenal invasion (SPG: 40.0% vs 4.9%, p=0.002; TPG: 28.6% vs 2.9%, p<0.001) than patients with an MBO located more than 2 cm from the AOV.
Conclusions
The SPG and TPG showed similar results in terms of stent patency and rate of adverse events. However, patients with an MBO located within 2 cm from the AOV had a higher percentage of duodenal invasion with shorter stent patency than those with an MBO located more than 2 cm from the AOV, regardless of stent position.

Keyword

Self expandable metallic stents; Adverse events; Bile duct neoplasms; Ampulla of Vater; Endoscopic retrograde cholangiopancreatography