Int J Arrhythm.  2023 Jun;24(2):14. 10.1186/s42444-023-00098-y.

A successful case of left bundle branch area pacing using stylet‑driven pacing leads with a steerable delivery sheath in patients with structural heart disease

Affiliations
  • 1Department of Cardiovascular Medicine, Won Kwang University Medical School, Iksan, Korea
  • 2Department of Cardiovascular Medicine, Chosun University Medical School, Gwangju, Korea
  • 3Division of Cardiology of Chosun University Hospital, Donggu, Gwangju, Korea

Abstract

Background
Left bundle branch area pacing (LBBAP) has emerged as a novel form of physiological pacing. However, few physicians have used stylet-driven pacing leads with a steerable delivery sheath for left fascicular bundle pacing.
Case presentation
A 75-year-old man with a history of heart valve surgery and atrial fibrillation arrived at the emergency department complaining of exertional dyspnea and general weakness. Twelve-lead electrocardiography showed atrial fibrillation with regular RR intervals with escape beats of 41 beats per minutes, which suggested complete atrioventricular block. Two-dimensional echocardiography showed global hypokinesia and a huge atrium. Given the impaired left ventricular (LV) function and the deleterious effects of right ventricular apical pacing, conduction system pacing was attempted. Mapping of His bundle and left bundle potential using a steerable delivery sheath was attempted; however, it did not appear prominent. Several attempts to deploy the lead failed because the sheath was malpositioned such that the lead could not move perpendicularly. Reshaping the sheath allowed for an extended reach so that the pacing lead could be positioned inferior to the previously attempted site toward the apex, deep inside the septum, where the distal left septal fascicle was captured rather than the left bundle branch trunk. During the 6-month follow-up period, the patient was free of any symptoms. Capture threshold and sensing value were stable and follow-up echocardiography showed slightly improved LV function.
Conclusions
Left fascicular bundle pacing may be an alternative strategy when conventional pacing using styletdriven pacing leads with a steerable delivery sheath fails to capture the left branch bundle in patients with challenging anatomy.

Keyword

Artificial pacemaker; Bundle of his; Atrioventricular block