Background
The number of revision total knee arthroplasty (TKA) has been increasing. Although many studies have analyzed the causes of revision TKA in Western countries, a limited number of studies have analyzed changes in causes of or trends in revision TKA in Asia. This study analyzed and determined the frequency and causes of failures after TKA in our hospital. We also analyzed the differences and trends over the past 17 years.
Methods
A total of 296 revision TKAs performed in a single institution from 2003 to 2019 were analyzed. During the 17-year study period, patients who had undergone primary TKA between 2003 and 2011 were classified into a past group, while those who had undergone primary TKA from 2012 to 2019 were classified into a recent group. A revision performed within 2 years after primary TKA was defined as early revision. Further, differences in causes of revision TKA according to the interval from primary TKA to revision TKA were determined. The causes of revision TKA were analyzed through a comprehensive analysis of patients’ medical records.
Results
Overall, infection was the most common cause of failure (151/296 cases, 51.0%). Compared to the past group, the recent group had a relatively higher proportion of patients undergoing revision TKA for mechanical loosening (past group, 19.1% vs. recent group, 31.9%) and instability (11.2% vs. 13.5%) and a relatively lower proportion of patients undergoing revision TKA for infection (56.2% vs. 48.8%), polyethylene (PE) wear (9.0% vs. 2.9%), osteolysis (2.2% vs. 1.9%), and malalignment (2.2% vs. 1.0%). On comparison according to the interval from primary TKA to revision TKA, the rate of infection relatively decreased, whereas the rate of mechanical loosening and instability relatively increased in the late revision TKA compared to the early revision TKA.
Conclusions
Infection and aseptic loosening were the most common reasons of revision TKA in both past and recent groups. Compared to the past, revision TKA due to PE wear has decreased significantly and revision TKA due to mechanical loosening has relatively increased recently. Orthopedic surgeons need to be aware of recent trends in mechanisms of failure and should try to recognize and address the probable causes in TKA