J Cardiovasc Imaging.  2022 Oct;30(4):292-304. 10.4250/jcvi.2021.0141.

Distribution of Aortic Root Calcium in Relation to Frame Expansion and Paravalvular Leakage After Transcatheter Aortic Valve Implantation (TAVI): An Observational Study Using a Patient-specific Contrast Attenuation Coefficient for Calcium Definition and Independent Core Lab Analysis of Paravalvular Leakage

Affiliations
  • 1Department of Cardiology, Thoraxcenter, Erasmus Medical Center, Rotterdam, The Netherlands
  • 2Cardialysis Clinical Trials Management and Core Laboratories, Rotterdam, The Netherlands
  • 3Department of Radiology and Nuclear Medicine, Erasmus Medical Center, Rotterdam, The Netherlands

Abstract

BACKGROUND
Calcium is a determinant of paravalvular leakage (PVL) after transcatheter aortic valve implantation (TAVI). This is based on a fixed contrast attenuation value while X-ray attenuation is patient-dependent and without considering frame expansion and PVL location. We examined the role of calcium in (site-specific) PVL after TAVI using a patientspecific contrast attenuation coefficient combined with frame expansion.
METHODS
57 patients were included with baseline CT, post-TAVI transthoracic echocardiography and rotational angiography (R-angio). Calcium load was assessed using a patient-specific contrast attenuation coefficient. Baseline CT and post-TAVI R-angio were fused to assess frame expansion. PVL was assessed by a core lab.
RESULTS
Overall, the highest calcium load was at the non-coronary-cusp-region (NCR, 436 mm3 ) vs. the right-coronary-cusp-region (RCR, 233 mm3 ) and the left-coronary-cuspregion (LCR, 244 mm3 ), p < 0.001. Calcium load was higher in patients with vs. without PVL (1,137 vs. 742 mm3 , p = 0.012) and was an independent predictor of PVL (odds ratio, 4.83, p = 0.004). PVL was seen most often in the LCR (39% vs. 21% [RCR] and 19% [NCR]). The degree of frame expansion was 71% at the NCR, 70% at the RCR and 74% at the LCR without difference between patients with or without PVL.
CONCLUSIONS
Calcium load was higher in patients with PVL and was an independent predictor of PVL. While calcium was predominantly seen at the NCR, PVL was most often at the LCR. These findings indicate that in addition to calcium, specific anatomic features play a role in PVL after TAVI.

Keyword

Aortic stenosis; Transcatheter aortic valve replacement; Multimodal imaging