Gut Liver.  2022 Sep;16(5):716-725. 10.5009/gnl210287.

Correlation between Surrogate Quality Indicators for Adenoma Detection Rate and Adenoma Miss Rate in Qualified Colonoscopy, CORE Study: KASID Multicenter Study

Affiliations
  • 1Department of Internal Medicine, Soonchunhyang University College of Medicine, Seoul, Korea
  • 2Department of Digestive Disease Center, Soonchunhyang University Hospital, Seoul, Korea
  • 3Department of Data Innovation, Soonchunhyang University College of Medicine, Seoul, Korea
  • 4Department of Internal Medicine, Kyung Hee University School of Medicine, Seoul, Korea
  • 5Department of Internal Medicine, Soonchunhyang University College of Medicine, Cheonan, Korea
  • 6Department of Internal Medicine, Dankook University College of Medicine, Cheonan, Korea
  • 7Department of Internal Medicine, College of Medicine, The Catholic University of Korea, Seoul, Korea

Abstract

Background/Aims
The adenoma detection rate (ADR) does not reflect the complete detection of every adenoma during colonoscopy; thus, many surrogate indicators have been suggested. This study investigated whether the ADR and surrogate quality indicators reflect the adenoma miss rate (AMR) when performing qualified colonoscopy.
Methods
We performed a prospective, multicenter, cross-sectional study of asymptomatic examinees aged 50 to 75 years who underwent back-to-back screening colonoscopies by eight endoscopists. The ADR and surrogate quality indicators, including polyp detection rate, total number of adenomas per colonoscopy, additional adenomas found after the first adenoma per colonoscopy (ADR-Plus), and total number of adenomas per positive participant, were calculated for the prediction of AMR.
Results
A total of 371 back-to-back colonoscopies were performed. There was a significant difference in ADRs (range, 44% to 75.4%; p=0.024), polyp detection rates (range, 56% to 86.9%; p=0.008) and adenomas per positive participants (range, 1.19 to 2.30; p=0.038), and a tendency of a difference in adenomas per colonoscopy (range, 0.62 to 1.31; p=0.051) and ADR-Plus (range, 0.13 to 0.70; p=0.054) among the endoscopists. The overall AMR was 20.1%, and AMRs were not different (range, 13.9 to 28.6; p>0.05) among the endoscopists. No quality indicators were significantly correlated with AMR. The number of adenomas found during the first colonoscopy was an independent factor for increased AMR (odds ratio, 1.79; p<0.001).
Conclusions
The colonoscopy quality indicators were significantly different among high-ADR endoscopists, and none of the quality indicators reflected the AMR of good quality colonoscopy performances. The only factor influencing AMR was the number of adenomas detected during colonoscopy.