Korean J Vet Res.  2022 Mar;62(1):e8. 10.14405/kjvr.20210047.

Image quality assessments of focal spot size on radiographic images in dogs

Affiliations
  • 1Department of Veterinary Medical Imaging, College of Veterinary Medicine and Institute of Animal Medicine, Gyeongsang National University, Jinju, 52828, Korea

Abstract

The aim of this prospective study was to investigate the effects of focal spot size of X-ray tube on sharpness of clinical radiographic images of dogs and cats. Radiographic images of 24 stifle joints, 15 carpi, 18 lumbar spines, 61 thoraxes, and 47 abdomens of 102 dogs and 4 cats were obtained in the present study, using 2 X-ray tubes with nominal focal spots of 2.0 mm and 0.6 mm, respectively. The sharpness of specific anatomical structures in all the images of 5 projections was assessed. The radiographic sharpness of various anatomical structures of lumbar spine and cortex of stifle with fine focal spot was increased significantly compared with broad focal spot images. In addition, the blurred motion was significantly higher in the fine focal spot images of thorax. In conclusion, our study suggests that a selective use of fine foci for imaging of lumbar spine or cortex of stifle enhanced radiographic sharpness.

Keyword

geometric unsharpness; focal spot size; radiographic image quality; dogs