Kosin Med J.  2022 Mar;37(1):89-92. 10.7180/kmj.21.047.

Emergency rescue stent grafting for a ruptured degenerated graft that bypassed coarctation of the aorta: a case report

Affiliations
  • 1Department of Thoracic and Cardiovascular Surgery, Daejeon Eulji University Hospital, Eulji University School of Medicine, Daejeon, Korea
  • 2Department of Thoracic and Cardiovascular Surgery, Dongguk University Ilsan Hospital, Dongguk University School of Medicine, Ilsan, Korea
  • 3Department of Thoracic and Cardiovascular Surgery, Kosin University Gospel Hospital, Kosin University College of Medicine, Busan, Korea

Abstract

A 33-year-old man who had undergone bypass from the distal aortic arch to the proximal descending thoracic aorta with a Dacron graft to treat coarctation of the aorta 20 years prior presented to the emergency department with massive hemoptysis. He was diagnosed with a graft-to-bronchial fistula. After thoracic endovascular aneurysm repair through the coarctation, aortic replacement was performed 3 weeks later. Therefore, emergency-rescue thoracic endovascular aneurysm repair can be considered for preventing aortic rupture.

Keyword

Case reports; Coarctation of aorta; Dacron; Endovascular procedures; Ruptured aortic aneurysm

Figure

  • Fig. 1. Computed tomography scans from 8 years ago (A) and at presentation (B). Twisted graft with aneurysmal change at the rupture spot (arrow in C).

  • Fig. 2. Computed tomography (CT) scan after thoracic endovascular aneurysm repair, without any definite endoleak (A). The new Dacron graft in the operative findings (B) and a postoperative CT scan (C).


Reference

References

1. Kawata M, Morota T, Takamoto S, Kubota H, Kitahori K. Non-anastomotic rupture in the guideline of a Dacron thoracic aortic graft. J Vasc Surg. 2005; 42:573.
Article
2. Tomasi J, Belhaj Soulami R, Rolland M, Verhoye JP. Endovascular repair of a Dacron pseudoaneurysm in an ascending-to-descending aortic bypass. Aorta (Stamford). 2020; 8:104–6.
Article
3. Lee Y, Kim GJ, Kim YE, Hong SW, Lee JT. Non-anastomotic rupture of a woven Dacron graft in the descending thoracic aorta treated with endovascular stent grafting. Korean J Thorac Cardiovasc Surg. 2016; 49:465–7.
Article
4. Di Bartolomeo R, Berretta P, Petridis FD, Folesani G, Cefarelli M, Di Marco L, et al. Reoperative surgery on the thoracic aorta. J Thorac Cardiovasc Surg. 2013; 145(3 Suppl):S78–84.
Article
5. Taggart NW, Minahan M, Cabalka AK, Cetta F, Usmani K, Ringel RE, et al. Immediate outcomes of covered stent placement for treatment or prevention of aortic wall injury associated with coarctation of the aorta (COAST II). JACC Cardiovasc Interv. 2016; 9:484–93.
Full Text Links