Ultrasonography.  2022 Apr;41(2):373-381. 10.14366/usg.21175.

Comparison between conventional duplex ultrasonography and the dual-gate Doppler mode for hemodynamic measurements of the carotid arteries

Affiliations
  • 1Vascular Medicine, University Hospital Center, Angers, France
  • 2Emergency, University Hospital Center, Angers, France
  • 3Anesthesia and Critical Care, Hospices Civils, Lyon, France
  • 4Vascular Medicine, University Hospital Rangueil, Toulouse, France
  • 5Sports Medicine, University Hospital Center, Angers, France
  • 6MitoVasc Institute UMR CNRS 6015/INSERM 1083, Faculty of Medicine, Angers University, Angers, France

Abstract

Purpose
This study investigated the correlations of hemodynamic parameters measured to quantify stenosis between the gold-standard duplex ultrasonography and the dual-gate Doppler mode.
Methods
Patients examined due to suspicion of carotid artery stenosis or for surveillance of known stenosis were invited to participate in this prospective single-center study. Upon acceptance, the hemodynamic characteristics of the carotid arteries were determined successively in standard duplex and dual-gate Doppler modes. The correlations between the two modes were analyzed by computing Pearson coefficients (r2) and Lin concordance coefficients (ρc). The degree of agreement between the two methods was visualized using Bland-Altman graphical representations.
Results
The correlation between internal carotid artery peak systolic velocity measured by standard duplex ultrasonography and dual-gate Doppler mode was good (r2=0.642). The same high level of correlation was observed for the carotid ratio (r2=0.544). However, the Bland-Altman graphical representation and the Lin concordance coefficients (ρc=0.75 and ρc=0.74 for the internal carotid artery peak systolic velocity and carotid ratio, respectively) showed that a lack of precision generated some discrepancies between the two measurement methods.
Conclusion
Although some discrepancies were observed, the hemodynamic measurements were closely correlated between the two ultrasonography modes. Therefore, the dual-gate Doppler mode may have obvious advantages over conventional ultrasonography, offering interesting development possibilities.

Keyword

Carotid arteries stenosis; Diagnostic method; Ultrasonography; Hemodynamics; Dual-gate Doppler