Gut Liver.  2022 Mar;16(2):259-268. 10.5009/gnl210092.

Efficacy and Safety of TJP-008 Compared to 2 L PEG with Ascorbate in Colon Cleansing: A Randomized Phase 3 Trial

Affiliations
  • 1Division of Gastroenterology and Hepatology, Department of Internal Medicine, Ansan Hospital, Korea University College of Medicine, Ansan, Korea.
  • 2Department of Gastroenterology, University of Ulsan College of Medicine, Seoul, Korea.
  • 3Division of Gastroenterology, Department of Internal Medicine, College of Medicine, The Catholic University of Korea, Seoul, Korea.
  • 4Department of Internal Medicine, Ewha Womans University College of Medicine, Seoul, Korea.
  • 5Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Korea.
  • 6Division of Gastroenterology and Hepatology, Department of Internal Medicine, Anam Hospital, Korea University College of Medicine, Seoul, Korea.

Abstract

Background/Aims
Polyethylene glycol (PEG)-based bowel preparations are effective cleansing agents for colonoscopy. However, they require relatively large volumes to be used even with agents such as 2 L PEG with ascorbate (2LPEG). This phase 3, randomized, single-blinded, multicenter, parallel-group study compared the efficacy of 1 L PEG with high-dose ascorbate, TJP-008, to 2LPEG.
Methods
Patients undergoing colonoscopy were randomized (1:1:1) to receive TJP-008 as 1-day split dose (TJP-008-1) or 2-day split dose (TJP-008-2) regimen or to receive 2LPEG as a 2-day split dose regimen. Cleansing efficacy was evaluated using the Harefield Cleansing Scale. The primary endpoint was overall bowel cleansing success. Full analysis set (FAS) and per protocol set (PPS) analyses were performed.
Results
Of the 314 screened patients, efficacy was assessed in the following patient numbers (FAS/PPS): total (293/285), TJP-008-1 (98/94), TJP-008-2 (97/95), and 2LPEG (98/96). FAS revealed noninferiority between TJP-008 and 2LPEG with regard to overall success (TJP-008-2, 99.0%; TJP-008-1, 95.9%; 2LPEG, 94.9%; p=0.100 and p=0.733, respectively). PPS also showed noninferiority (p=0.721 and p=0.211, respectively). However, the PPS analyses showed a higher bowel cleansing score for TJP-008-2 for high-quality cleansing in the right colon (TJP-008-2 83.2% vs 2LPEG 62.5%; p=0.005).
Conclusions
TJP-008 is a new low-volume cleansing agent with a colon cleansing efficacy comparable to that of standard 2LPEG that exhibits significant safety and tolerability

Keyword

Colonoscopy; Cathartics; Polyethylene glycols; Ascorbic acid; Safety
Full Text Links
  • GNL
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr