J Korean Ophthalmol Soc.  2022 Feb;63(2):134-141. 10.3341/jkos.2022.63.2.134.

Clinical Results of Cataract Surgery Using the ARTIS ® PL E Intraocular Lens

Affiliations
  • 1Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea
  • 2Corneal Dystrophy Research Institute, Yonsei University College of Medicine, Seoul, Korea
  • 3Saevit Eye Hospital, Goyang, Korea

Abstract

Purpose
To compare the clinical outcomes of cataract surgery using the ARTIS ® PL E (Cristalens Industrie, Lannion, France) intraocular lens (IOL) and conventional Tecnis ® ZCB00 (Johnson & Johnson Vision, Santa Ana, CA, USA) IOL.
Methods
This retrospective study examined patients who underwent in-the-bag implantation of either an ARTIS ® PL E (33 eyes, group A) or Tecnis ® ZCB00 (45 eyes, group B) IOL after phacoemulsification performed by a single surgeon. Best-corrected visual acuity (BCVA), spherical equivalent, and higher-order aberrations (HOA) were measured 1 and 3 months after cataract surgery.
Results
Preoperative BCVA did not differ significantly in groups A and B. Postoperative BCVA at 1 and 3 months improved significantly (p < 0.001) in both groups compared to preoperative baseline BCVA. At 1 and 3 months postoperatively, total HOA, spherical aberration, and coma were significantly lower compared to the preoperative baseline HOA (p < 0.05) in both groups. However, there were no significant differences in the trefoil values 1 and 3 months postoperatively compared to the preoperative baseline in both groups. The absolute refractive error 3 months postoperatively was 0.27 ± 0.20 (group A) and 0.28 ± 0.20 (group B), both within ± 0.50 diopters of the targeted goal diopter; there were no significant differences in the accuracy or predictability of the IOL power calculation in both groups (p = 0.390, p = 0.959). The absolute refractive error 1 and 3 months postoperatively did not differ significantly; there were no significant differences in the stability of both IOLs (p = 0.482, p = 0.372).
Conclusions
Conventional cataract surgery using the ARTIS ® PL E IOL significantly increased the BCVA, while obtaining comparable clinical results to the verified Tecnis ® ZCB00 IOL in postoperative visual acuity and HOA.

Keyword

Femtosecond laser-assisted; Cataract surgery; Phacoemulsification; Intraocular lens; Higher order aberration
Full Text Links
  • JKOS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr