Clin Orthop Surg.  2022 Mar;14(1):41-47. 10.4055/cios21041.

Risk Factors and Outcomes Associated with Intraoperative Fractures during Short-Stem Total Hip Arthroplasty for Osteonecrosis of the Femoral Head

Affiliations
  • 1Department of Orthopedics, All India Institute of Medical Sciences (AIIMS), Teaching Block, New Delhi, India
  • 2Department of Community Ophthalmology, All India Institute of Medical Sciences (AIIMS), New Delhi, India

Abstract

Background
Young age in osteonecrosis of the femoral head (ONFH) demands bone-preserving, short-stem arthroplasty. Several designs including neck-preserving stems and neck-resecting, shortened, standard stems are classified as short stems. There is a paucity of literature investigating risk factors and outcomes of intraoperative complications of neck preserving, short-stem arthroplasty in ONFH.
Methods
A total of 107 hips operated with METHA short-stem arthroplasty for ONFH were retrospectively evaluated. The mean age of patients was 43.7 years (range, 27–60 years). Nine patients had an intraoperative fracture. Seven hips received prophylactic cerclage wiring for poor bone quality. Patients were invited for clinical and radiological evaluation at the latest follow-up.
Results
The mean follow-up of patients was 47.2 months. Significant association with intraoperative fractures and the need for prophylactic cerclage wiring were found in steroids-, alcohol-, and chronic renal failure-induced ONFH. However, patient sex, body mass index, traumatic/idiopathic ONFH, previous implant in situ, prosthesis size, and single-sitting bilateral total hip replacement (THA) were not the risk factors. All hips showed signs of osteointegration at final follow-up. No revision was done during the study period for any cause.
Conclusions
METHA short-stem THA offers excellent functional and radiological outcomes in ONFH. However, precaution must be exercised in patients with steroids-, alcohol-, and renal disorders-induced ONFN due to poor bone quality and higher chances of intraoperative fractures. Also, additional measures such as the use of a high-speed burr and prophylactic cerclage wiring in ONFH may allow predictable and safe use of short stems.

Keyword

Hip; Osteonecrosis; Femur head necrosis; Arthroplasty; Short stem arthroplasty