Nucl Med Mol Imaging.  2021 Dec;55(6):302-310. 10.1007/s13139-021-00716-4.

Comparison between Tc-99 m DTPA and Tc-99 m MAG3 Renal Scintigraphy for Prediction of Early Adverse Outcome After Kidney Transplantation

Affiliations
  • 1Department of Epidemiology and Biostatistics, Faculty of Public Health, Khon Kaen University, Khon Kaen, Thailand
  • 2Division of Nuclear Medicine, Department of Radiology, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand
  • 3Division of Nephrology, Department of Internal Medicine, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand

Abstract

Purpose
Renal scintigraphy (RS) with either technetium-99 m diethylene-triamine-pentaacetate (Tc-99 m DTPA) or technetium-99 m mercaptoacetyltriglycine (Tc-99 m MAG3) has both been used to evaluate early allograft function after kidney transplantation (KT). This study was done to compare the predictive performance of RS using these two radiopharmaceuticals for prediction of outcomes during first 3 months of KT.
Methods
This retrospective study included patients who received KT then underwent both Tc-99 m DTPA and Tc-99 m MAG3 RS, successively. Receiver operating characteristic (ROC) curve analysis was used to determine the predictiveness of RS parameters on early clinical adverse outcomes of either (1) graft-related death, (2) need for graft resection, (3) delayed graft function requiring temporary dialysis, or (4) a serum creatinine level of ≥ 2.0 mg/dL at three months post-KT, as well as to predict biopsy-confirmed acute tubular necrosis and acute rejection.
Results
Of 187 patients included, 77 (41.2%) had at least one early adverse clinical outcome. Tc-99 m MAG3 RS was more predictive than Tc-99 m DTPA RS, in terms of AUCROC, in three parameters including time to peak (0.754 vs. 0.516, p-value 0.0001), 20-min to peak ratio (0.762 vs. 0.651, p-value 0.006), and 20-min to 3-min ratio (0.823 vs. 0.699, p-value 0.0005). Acute tubular necrosis was better predicted by Tc-99 m MAG3 RS while both were at best only modest in predicting acute rejection.
Conclusion
Three parameters which, when obtained from Tc-99 m MAG3 RS, had superior predictiveness compared with Tc-99 m DTPA RS, including time to peak, 20-min to peak ratio, and 20-min to 3-min ratio.

Keyword

Renal transplantation; Renal scintigraphy; Radionuclide imaging; Graft complication ; Graft outcome
Full Text Links
  • NMMI
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr