Yonsei Med J.  2022 Jan;63(1):95-103. 10.3349/ymj.2022.63.1.95.

Meta-Analysis of the Diagnostic Efficacy of the Luminex xTAG Respiratory Viral Panel FAST v2 Assay for Respiratory Viral Infections

Affiliations
  • 1Department of Clinical Laboratory Medicine, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China.
  • 2Department of Clinical Medicine, The Third Clinical School of Guangzhou Medical University, Guangzhou, China.
  • 3Department of Pediatrics, The Pediatrics School of Guangzhou Medical University, Guangzhou, China.
  • 4Key Laboratory for Major Obstetric Diseases of Guangdong Province, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China.
  • 5Key Laboratory of Reproduction and Genetics of Guangdong Higher Education Institutes, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China.

Abstract

Purpose
Acute respiratory viral infections pose significant morbidity and mortality, making it essential to diagnose respiratory viral infections rapidly. In this study, the diagnostic efficacy of the Luminex xTAG Respiratory Virus Panel (RVP) FAST v2 test was evaluated on respiratory viral infections.
Materials and Methods
Information was retrieved from electronic databases, including Embase, Web of Science, PubMed, and Cochrane Library, for systematic review. Studies that fulfilled predefined inclusion criteria were included. After the extraction of information, statistical software was utilized for quality evaluation, data analysis, and assessment of publication bias.
Results
Eighty groups in fourfold tables from nine articles were included to perform statistical analyses. Therein, the mean specificity and mean sensitivity of Luminex xTAG RVP FAST v2 test for the detection of respiratory viral infections were 0.99 (0.98–0.99) and 0.88 (0.87–0.90), respectively. Additionally, the negative and positive likelihood ratios were 0.14 (0.11–0.19) and 87.42 (61.88– 123.50), respectively. Moreover, the diagnostic odds ratio and area under the curve of summary receiver operating characteristic were 714.80 and 0.9886, respectively.
Conclusion
The Luminex xTAG RVP FAST v2 test could be a reliable and rapid diagnostic method for multiple respiratory viral infections.