Korean J Neurotrauma.  2021 Oct;17(2):199-203. 10.13004/kjnt.2021.17.e30.

Emergent Vertebral Artery Embolization during C12 Screw Fixation for Rheumatoid Arthritis

Affiliations
  • 1Department of Neurosurgery, Yonsei University Wonju College of Medicine, Wonju Severance Christian Hospital, Wonju, Korea

Abstract

The subaxial screw fixation technique is commonly used for fixation in a wide range of cervical diseases, including traumatic, degenerative, and neoplastic diseases, rheumatoid arthritis (RA), and spondyloarthropathy. Although it is regarded as a relatively safe procedure, several complications may be encountered during surgery, such as vertebral artery (VA) and nerve root injuries, facet violation, and mass fracture. We report a case of endovascular embolization after VA injury during a high cervical spinal surgery. A 48-year-old woman was scheduled for C-1-2-3 posterior fixation. Plain radiography of the cervical spine revealed a severely unstable state. During dissection around the C1 lateral mass on the right side, sudden brisk arterial bleeding was observed. On vertebral angiography, flow voiding was noted above the right V3 portion. After checking patent collateral flow from the contralateral VA, routine coil embolization was performed to pack the V3 segment. Iatrogenic vascular injuries due to spinal surgery are rare but serious complications. For patients with RA, we recommend careful preoperative evaluation before a high cervical surgical procedure to avoid iatrogenic VA injury and endovascular interventions that are safe and effective in the diagnosis and treatment of such vascular injuries.

Keyword

Vertebral artery; Rheumatoid Arthritis; Therapeutic Embolization
Full Text Links
  • KJN
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr