Abstract

An 87-year-old man presented with a saccular aneurysm at the proximal descending thoracic aorta. As computed tomography revealed a shaggy aorta, we planned hybrid thoracic endovascular aortic repair (TEVAR) with embolic protection devices (EPDs) in both internal carotid arteries to prevent a cerebrovascular accident. We inserted an Emboshield NAV 6 Embolic Protection System (Abbott Vascular, Abbott Park, IL, USA) into both internal carotid arteries before performing the TEVAR procedure. The patient was discharged from the hospital on postoperative day 4 without any neurological complications.

Keyword

Aneurysm; Aorta; Arch; Endovascular procedures; Cerebral protection; Case report