Gut Liver.  2020 Nov;14(6):826-832. 10.5009/gnl19123.

Utility of Contrast-Enhanced Harmonic Endoscopic Ultrasound for the Guidance and Monitoring of Endoscopic Radiofrequency Ablation

Affiliations
  • 1Department of Internal Medicine, Dankook University Hospital, Dankook University College of Medicine, Cheonan, Korea
  • 2Department of Internal Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea

Abstract

Background/Aims
Interventional endoscopists may utilize contrast-enhanced harmonic endoscopic ultrasound (CEHEUS) for image guidance during radiofrequency ablation (RFA) because of its capability to delineate real-time tumor perfusion dynamics. The purpose of this study was to assess the utility of CEH-EUS for the guidance and monitoring of en-doscopic RFA.
Methods
Nineteen consecutive patients with solid abdominal tumors who underwent CEH-EUS and endo-scopic RFA were included. The extent of the ablation was as-sessed by CEH-EUS at 5 to 7 days after RFA. Additional RFAs were performed under CEH-EUS guidance.
Results
The diag-noses were as follows: nonfunctioning neuroendocrine tumor (n=13), solid pseudopapillary neoplasm (SPN) (n=2), insu-linoma (n=1), left adrenal adenoma (n=2), and left adrenal oligometastasis (n=1). Pre-CEH-EUS findings revealed that 17 cases showed hyperenhanced patterns and two cases of SPN showed isoenhanced patterns. CEH-EUS-assisted RFA was technically feasible in all 19 patients. After the first RFA session, seven patients of the treated tumors showed the disappearance of intratumoral enhancement on CEH-EUS, whereas 12 showed residual contrast enhancement. Twelve patients with incomplete ablation were further treated with additional RFA under real-time CEH-EUS guidance. Radiolog-ic complete response was observed in 13 patients (68.4%). Among the 35 ablation procedures, the only adverse events were two episodes of pancreatitis (5.7%; 1 moderate and 1mild). During the median follow-up of 28 months, the local recurrence rate was 7.7%.
Conclusions
The application of CEH-EUS for RFA could be helpful in assessing early treat-ment response after ablation and targeting residual viable tumors during additional ablation sessions.

Keyword

Contrast agent; Endosonography; Radiofrequency ablation