Ultrasonography.  2020 Oct;39(4):367-375. 10.14366/usg.19061.

Determining the optimal timing of screening spinal cord ultrasonography to detect filum terminale lipoma in infants

Affiliations
  • 1Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, Korea
  • 2Department of Radiology, King Faisal General Hospital, Al-Hofuf, Saudi Arabia
  • 3Department of Pediatric Neurosurgery, Severance Children’s Hospital, Yonsei University College of Medicine, Seoul, Korea
  • 4Division of Neonatology, Department of Pediatrics, Severance Children’s Hospital, Yonsei University College of Medicine, Seoul, Korea

Abstract

Purpose
The purpose of this study was to identify the optimal timing for screening spinal cord ultrasonography (US) to detect filum terminale lipoma in infants.
Methods
We retrospectively reviewed infants (<12 months old) who underwent repeated spinal cord US between April 2011 and January 2019. We excluded infants if they only had one US examination, or if they had lesions other than filum terminale lipoma. Infants with filum terminale lipoma on magnetic resonance imaging were included in the lipoma group and the others in the control group. A linear mixed model was used to assess differences in the growth pattern of filum terminale thickness by age and group. The cutoff thickness on US and its diagnostic performance were assessed according to age.
Results
Among 442 infants with 901 US examinations, 46 were included in the lipoma group and 58 in the control group. Sixty-seven infants had unmeasurable filum terminale thickness on initial US, including 55 neonates (82.1%) before 1 month of age. The lipoma group had significantly greater filum terminale thickness than the control group (P<0.001). Thickness increased with age in the lipoma group (P=0.027). The sensitivity of US was 87.5% and the area under the receiver operating characteristic curve was 0.949 (95% confidence interval, 0.849 to 0.991) with a cutoff value of 1.1 mm in 4- to 6-month-old infants.
Conclusion
Screening spinal cord US could effectively diagnose filum terminale lipoma in 4- to 6-month-old infants with a cutoff thickness of 1.1 mm. Spinal cord US can be used to screen young infants with intraspinal abnormalities.

Keyword

Infants; Spinal cord; Ultrasonography; Cauda equina; Retrospective studies