J Korean Orthop Assoc.  1975 Dec;10(4):395-399. 10.4055/jkoa.1975.10.4.395.

The Sliding Compression Hip Screw Fixation in the Treatement of the Proximal End of the Femur: Report of 10 cases

Affiliations
  • 1Department of Orthopedic surgery. Han-il Hospital, Seoul, Korea.

Abstract

Between May 1974 and May 1975. ten patients with intertrochanteric or femoral neck fractures were treated by siding compression hip screw fixation. The time allowed to weight bearing on the affected extremity was within 10 days in 5 patients, In the other 5 patients, who had other accompanying fractures and who had passed more than 3 weeks from the time of injury, weight bearing on the affected side was permitted from 6 to 8 weeks of operation. The average time for fracture union in this series was about 4 months. No delayed unions were observed in the 8 patients who were followed more than 6 months.