STUDY DESIGN: Retrospective chart review. PURPOSE: This study evaluated long-term surgical outcomes of computer-assisted reconstruction using transarticular or cervical pedicle screws for cervical spine lesions caused by advanced rheumatoid arthritis (RA). OVERVIEW OF LITERATURE: We routinely employ C1-C2 transarticular and cervical pedicle screw instrumentation to reconstruct advanced and unstable RA cervical lesions. However, few reports are available on the long-term results of surgical reconstruction for rheumatoid cervical disorders, particularly regarding cervical pedicle screw fixation.
METHODS
Six subjects (all female) with RA cervical lesions who underwent atlantoaxial or occipitocervical fixation and were followed for at least 10 years were retrospectively studied. A frameless, stereotactic, optoelectronic, computed tomography-based image guidance system was used for correct screw placement. Variables including the Japanese Orthopaedic Association score, EuroQol, Ranawat value, and C2-C7 angle before and 2, 5, and 10 years after surgery were assessed along with the occurrence of subaxial subluxation (SAS).
RESULTS
Mean age at initial surgery was 58.2±7 years (range, 51-68 years), and mean follow-up period was 141±11 months (range, 122-153 months). Lesions included atlantoaxial subluxation (AAS, n=2) and AAS+vertical subluxation (n=4). Mean C2-C7 lordotic angle before and 2, 5, and 10 years after surgery was 20.1°±6.1°, 21.0°±4.0°, 18.8°±4.7°, and 17.8°±5.3°, respectively. SAS did not occur in cases maintaining the C2-C7 lordotic angle. In two cases where the C2-C7 lordotic angle declined from 5 years postoperatively, SAS occurred at the C2-C3 level in one and at the C4-C5 level in the other, both of which required reoperation.
CONCLUSIONS
Patients with rheumatoid cervical lesions who undergo atlantoaxial or occipitocervical fixation using C1-C2 transarticular or pedicle screws carry a risk of SAS for up to 10 years postoperatively, which may require reoperation.

Keyword

Ten-year; Rheumatoid; Cervical; Subaxial subluxation

MeSH Terms

Arthritis, Rheumatoid
Asian Continental Ancestry Group
Follow-Up Studies
Humans
Pedicle Screws
Reoperation
Retrospective Studies
Spine*
Full Text Links
  • ASJ
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr