Asian Spine J.  2019 Apr;13(2):248-253. 10.31616/asj.2018.0169.

Early Fusion Status after Posterior Lumbar Interbody Fusion with Cortical Bone Trajectory Screw Fixation: A Comparison of Titanium-Coated Polyetheretherketone Cages and Carbon Polyetheretherketone Cages

Affiliations
  • 1Department of Orthopaedic Surgery, Japan Community Healthcare Organization Osaka Hospital, Osaka, Japan. sakaura04061023@yahoo.co.jp
  • 2Department of Orthopaedic Surgery, Kansai Rosai Hospital, Amagasaki, Japan.

Abstract

STUDY DESIGN: Retrospective cohort study. PURPOSE: We recently reported that when compared to posterior lumbar interbody fusion (PLIF) using traditional pedicle screw fixation, PLIF with cortical bone trajectory screw fixation (CBT-PLIF) provided favorable clinical outcomes and reduced the incidence of symptomatic adjacent segment pathology, but resulted in relatively lower fusion rates. Since titanium-coated polyetheretherketone (PEEK) cages (TP) could improve and accelerate fusion status after CBT-PLIF, early fusion status was compared between CBT-PLIF using TP and carbon PEEK cages (CP). OVERVIEW OF LITERATURE: A systematic review demonstrated that clinical studies at this early stage show similar fusion rates for TP compared to PEEK cages.
METHODS
We studied 36 consecutive patients undergoing CBT-PLIF with TP (TP group) and 92 undergoing CBT-PLIF with CP (CP group). On multiplanar reconstruction computed tomography (MPR-CT) at 6 months postoperatively, vertebral endplate cysts (cyst signs) were evaluated and classified as diffuse or local cysts. Early fusion status was assessed by dynamic plain radiographs and MPR-CT at 1 year postoperatively.
RESULTS
The incidences of cyst signs, diffuse cysts, and early fusion rate in the TP and CP groups were 38.9% and 66.3% (p<0.01), 16.7% and 32.6% (p=0.07), and 83.3% and 79.3% (p>0.05), respectively. Combining the two groups, 22 of 36 patients with diffuse cysts had nonunion at 1-year follow-up, compared to only three of 92 patients with local cysts or without cyst signs (p<0.01).
CONCLUSIONS
Despite having fewer patients with endplate cysts at 6 months (a known risk factor for nonunion), the TP group had the same fusion rate as the CP group at 1-year follow-up. Thus, TP did not accelerate the fusion process after CBT-PLIF.

Keyword

Degenerative lumbar spondylolisthesis; Posterior lumbar interbody fusion; Cortical bone trajectory screw technique; Titanium-coated polyetheretherketone cage; Carbon polyetheretherketone cage

MeSH Terms

Carbon*
Cohort Studies
Follow-Up Studies
Humans
Incidence
Pathology
Pedicle Screws
Retrospective Studies
Risk Factors
Carbon
Full Text Links
  • ASJ
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr