Clin Should Elbow.  2019 Mar;22(1):16-23. 10.5397/cise.2019.22.1.16.

Patient-specific Guides Using 3-dimensional Reconstruction Provide Accuracy and Reproducibility in Reverse Total Shoulder Arthroplasty

Affiliations
  • 1Department of Orthopaedic Surgery, Kyungpook National University Hospital, Daegu, Korea. jpyoon@knu.ac.kr

Abstract

BACKGROUND
We aimed to evaluate whether the use of our novel patient-specific guide (PSG) with 3-dimensional reconstruction in reverse total shoulder arthroplasty (RTSA) would allow accurate and reliable implantation of the glenoid and humeral components.
METHODS
20 fresh-frozen cadaveric shoulders were used. The PSG group (n=10) and conventional group (n=10) was evaluated the accuracy and reproducibility of implant positioning between before and after surgery on the computed tomography image.
RESULTS
The superoinferior and anteroposterior offset in the glenoid component were 0.42 ± 0.07, 0.50 ± 0.08 in the conventional group and 0.45 ± 0.03, 0.46 ± 0.02 in the PSG group. The inclination and version angles were −1.93°± 4.31°, 2.27°± 5.91° and 0.46°± 0.02°, 3.38°± 2.79°. The standard deviation showed a smaller difference in the PSG group. The anteroposterior and lateromedial humeral canal center offset in the humeral component were 0.45 ± 0.12, 0.48 ± 0.15 in the conventional group and 0.46 ± 0.59 (p=0.794), 0.46 ± 0.06 (p=0.702) in the PSG group. The PSG showed significantly better humeral stem alignment.
CONCLUSIONS
The use of PSGs with 3-dimensional reconstruction reduces variabilities in glenoid and humerus component positions and prevents extreme positioning errors in RTSA.

Keyword

Reverse total shoulder arthroplasty; Patient-specific guide; Glenoid component; Humeral component; Positioning

MeSH Terms

Arthroplasty*
Cadaver
Humerus
Shoulder*
Full Text Links
  • CISE
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr