J Korean Ophthalmol Soc.  2018 Sep;59(9):819-826. 10.3341/jkos.2018.59.9.819.

Postoperative Refractive Errors after Air Tamponade with Posterior Capsulectomy during Combined Vitrectomy and Cataract Surgery

Affiliations
  • 1Sungmo Eye Hospital, Busan, Korea. heesyoon@dreamwiz.com
  • 2Bupyung St. Mary's Eye Clinic, Incheon, Korea.

Abstract

PURPOSE
To evaluate the postoperative refractive errors after air tamponade with posterior capsulectomy during combined vitrectomy and cataract surgery.
METHODS
Patients who underwent combined vitrectomy, cataract surgery, and air tamponade with or without posterior capsulectomy were reviewed. All patients were followed for 4 months after surgery. Preoperative characteristics such as anterior chamber depth, axial length, and refractive error were analyzed and refractive errors after the surgery were evaluated. The difference between the target refractions and final refractive errors after the surgery according to the biometry method, and intraocular lens power calculations, were observed.
RESULTS
Fourteen eyes of 14 patients who had combined vitrectomy and cataract surgery with posterior capsulectomy and air tamponade were classified as group A, and 10 eyes of 10 patients who had combined vitrectomy and cataract surgery with only air tamponade were classified as group B. The target refraction of group A measured with A-scan biometry using the Sanders-Retzlaff-Kraff/Theoretical (SRK/T) calculation was −0.21 ± 0.22 diopters (D), and the final refractive error at 9.5 (± 2.20) months after the surgery was −0.52 ± 0.54 D. The mean difference between the two was −0.32 ± 0.44 D. The target refraction of group B measured with A-scan biometry using the SRK/T calculation was −0.33 ± 0.29 D, and the final refractive error at 9.5 (± 2.20) months after the surgery was −0.27 ± 0.39 D. The mean difference between the two was 0.06 ± 0.53 D.
CONCLUSIONS
Posterior capsulectomy during combined vitrectomy and cataract surgery with air tamponade led to myopic shifts compared with no posterior capsulectomy with air tamponade during combined vitrectomy and cataract surgery. Performing posterior capsulectomy with air tamponade during combined vitrectomy and cataract surgery should, therefore, be carefully considered.

Keyword

Air tamponade; Cataract surgery; OA-2000 optical biometry; Posterior capsulectomy; Vitrectomy

MeSH Terms

Anterior Chamber
Biometry
Cataract*
Humans
Lenses, Intraocular
Methods
Refractive Errors*
Vitrectomy*

Figure

  • Figure 1. Clinical intraoperative photograph of the anterior segment showing the center of the posterior capsule removed using vitreous cutter. The posterior capsule was removed cur-vilinearly and completely.

  • Figure 2. Comparison of spherical equivalent correction of two different groups. The results of the group A (capsulectomy + air tamponade) (A) and group B (only air tamponade) (B) at last visit (mean postoperative 9.5 ± 2.20) months compared with predictive values from three different biometry devices and formulas combinations. SRK/T = Sanders-Retzlaff-Kraff/Theoretical.


Reference

References

1. Hsuan JD, Brown NA, Bron AJ, et al. Posterior subcapsular and nuclear cataract after vitrectomy. J Cataract Refract Surg. 2001; 27:437–44.
Article
2. Melberg NS, Thomas MA. Nuclear sclerotic cataract after abdominal in patients younger than 50 year of age. Ophthalmology. 1995; 102:1466–71.
3. Thompson JT. The role of patient age and intraocular gas use in abdominal progression after vitrectomy for macular holes and epiretinal membranes. Am J Ophthalmol. 2004; 137:250–7.
4. Grusha YO, Masket S, Miller KM. Phacoemulsification and lens implantation after pars plana vitrectomy. Ophthalmology. 1998; 105:287–94.
Article
5. Toda J, Kato S, Oshika T, Sugita G. Posterior capsule opacification after combined cataract surgery and vitrectomy. J Cataract Refract Surg. 2007; 33:104–7.
Article
6. Bhargava R, Kumar P, Phogat H, Chaudhary KP. Neodymium-yt-trium aluminium garnet laser capsulotomy energy levels for abdominal capsule opacification. J Ophthalmic Vis Res. 2015; 10:37–42.
7. Kim JH, Han SB, Lee SJ, Kim MS. Postoperative refractive errors after posterior capsulectomy during combined vitrectomy and abdominal surgery. J Korean Ophthalmol Soc. 2015; 56:709–14.
8. Suzuki Y, Sakuraba T, Mizutani H, et al. Postoperative refractive abdominal after simultaneous vitrectomy and cataract surgery. Ophthalmic Surg Lasers. 2000; 31:271–5.
9. Ohrloff C, Schalnus R, Rothe R, Spitznas M. Role of the posterior capsule in the aqueous-vitreous barrier in aphakic and abdominal eyes. J Cataract Refract Surg. 1990; 16:198–201.
10. Weinreb RN, Wasserstrom JP, Parker W. Neovascular glaucoma following neodymium-YAG laser posterior capsulotomy. Arch Ophthalmol. 1986; 104:730–1.
Article
11. Poliner LS, Christianson DJ, Escoffery RF, et al. Neovascular abdominal after intracapsular and extracapsular cataract extraction in abdominal patients. Am J Ophthalmol. 1985; 100:637–43.
12. Gimbel HV, Neuhann T. Development, advantages, and methods of the continuous circular capsulorhexis technique. J Cataract Refract Surg. 1990; 16:31–7.
Article
13. Gimbel HV. Posterior continuous curvilinear capsulorhexis and optic capture of the intraocular lens to prevent secondary opacification in pediatric cataract surgery. J Cataract Refract Surg. 1997; 23(Suppl 1):652–6.
Article
14. Galand A, van Cauwenberge F, Moosavi J. Posterior capsulorhexis in adult eyes with intact and clear capsules. J Cataract Refract Surg. 1996; 22:458–61.
Article
15. Jeoung JW, Chung H, Yu HG. Factors influencing refractive abdominals after combined phacoemulsification and pars plana abdominal: Results of a prospective study. J Cataract Refract Surg. 2007; 33:108–14.
16. Wagenfeld L, Hermsdorf K, Stemplewitz B, et al. Refractive abdominal in eyes with intraocular gas tamponade – results of a prospective controlled clinical trial. Clinical Ophthalmology. 2017; 11:993–8.
17. Falkner-Radler CI, Benesch T, Binder S. Accuracy of preoperative biometry in vitrectomy combined with cataract surgery for patients with epiretinal membranes and macular holes: results of a prospective controlled clinical trial. J Cataract Refract Surg. 2008; 34:1754–60.
18. Drexler W, Findl O, Menapace R, et al. Partial coherence abdominal: a novel approach to biometry in cataract surgery. Am J Ophthalmol. 1998; 126:524–34.
19. Haigis W, Lege B, Miller N, Schneider B. Comparison of abdominal ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis. Graefes Arch Clin Exp Ophthalmol. 2000; 238:765–73.
20. Lim HC, Kim KH, Shin MK, et al. Accuracy of predictive refraction in combined vitrectomy-cataract surgery for epiretinal membrane and macular hole. J Korean Ophthalmol Soc. 2015; 56:219–27.
Article
21. Haigis W. Intraocular lens power calculations. Thorofare: Slack Inc.;2003. p. 41–57.
22. Kim DY, Kim MJ, Kim JY, Tchah H. Comparison of formulas for intraocular lens power calculation installed in a partial coherence interferometer. J Korean Ophthalmol Soc. 2009; 50:523–8.
Article
23. Yi CH, Choi SH, Chung ES, Chung TY. Accuracy of the Haigis abdominal based on axial length and anterior chamber depth. J Korean Ophthalmol Soc. 2011; 52:175–81.
Full Text Links