World J Mens Health.  2014 Aug;32(2):120-122. 10.5534/wjmh.2014.32.2.120.

Successful Removal of an Intravesical Electrical Wire Cable

Affiliations
  • 1Department of Urology, Seoul National University Hospital, Seoul, Korea. volley@snu.ac.kr
  • 2Department of Urology, SMG-SNU Boramae Medical Center, Seoul, Korea.

Abstract

A few previous reports have described cases wherein electrical wire cables were inserted into the male urethra and bladder. Electrical wire cables are available at home and are easy to insert. However, after they coil in the patient's bladder, they are difficult to remove. In February 2013, a 30-year-old man presented to the emergency room of SMG-SNU Boramae Medical Center with a urethral foreign body. He had inserted an electrical wire cable into his urethra for the purpose of masturbation, despite having a regular sex partner and no underlying disease. A kidney-ureter-bladder radiography showed a tangled wire in his bladder and urethra. On the next day, we tried to remove the wire cystoscopically, but this proved to be impossible because of complex coiling and the slippery surface of the wire. A Pfannenstiel incision was made to remove the foreign body. No postoperative complications were noted.

Keyword

Foreign bodies; Masturbation; Urinary bladder

MeSH Terms

Adult
Emergency Service, Hospital
Foreign Bodies
Humans
Male
Masturbation
Postoperative Complications
Radiography
Urethra
Urinary Bladder

Figure

  • Fig. 1 Kidney-ureter-bladder abdominal radiography: a tangled wire in the bladder and urethra of a 30-year-old man.

  • Fig. 2 Gross appearance of the removed electrical wire cable.


Reference

1. De Bernardis G, Haecker FM. Curious foreign body in the bladder of an adolescent. J Pediatr Surg. 2012; 47:e39–e41.
Article
2. Stravodimos KG, Koritsiadis G, Koutalellis G. Electrical wire as a foreign body in a male urethra: a case report. J Med Case Rep. 2009; 3:49.
Article
3. Krpina K, Sotosek S, Oguić R, Maricić A, Valencić M, Fuckar Z. An unusual case of acute urinary retention. Acta Clin Croat. 2010; 49:177–179.
4. Irekpita E, Imomoh P, Kesieme E, Onuora V. Intravesical foreign bodies: a case report and a review of the literature. Int Med Case Rep J. 2011; 4:35–39.
5. Osca JM, Broseta E, Server G, Ruiz JL, Gallego J, Jimenez-Cruz JF. Unusual foreign bodies in the urethra and bladder. Br J Urol. 1991; 68:510–512.
Article
6. Moslemi MK, Sorani M. Self-inflicted male bladder foreign body: its endoscopic removal using a rigid cystoscope and a suprapubic forceps. Case Rep Urol. 2013; 2013:729013.
Article
7. Garg M, Kumar M, Sankhwar S, Singh V. Self-inflicted long complex urethro-vesical foreign body: is open surgery always needed? BMJ Case Rep. 2013; doi: 10.1136/bcr-2013-009216.
Article
8. Pal DK, Bag AK. Intravesical wire as foreign body in urinary bladder. Int Braz J Urol. 2005; 31:472–474.
Article
9. Ejstrud P, Poulsen J. Laparoscopic removal of an electric wire from the bladder. Br J Urol. 1997; 80:338.
Article
10. Ko YH, Kang SG, Kang SH, Park HS, Lee JG, Kim JJ, et al. Removal of long, complex foreign bodies from bladder using single laparoscopic port under pneumovesicum. J Laparoendosc Adv Surg Tech A. 2010; 20:639–642.
Article
11. Park HJ, Nam JK, Kim JM, Park NC. Foreign body in the Urethra. Korean J Androl. 2005; 23:47–50.
12. Hwang EC, Kim JS, Jung SI, Im CM, Yun BH, Kwon DD, et al. Delayed diagnosis of an intraurethral foreign body causing urosepsis and penile necrosis. Korean J Urol. 2010; 51:149–151.
Article
Full Text Links