J Korean Fract Soc.  1999 Jan;12(1):162-165.

Delayed Rupture of the Extensor Pollicis Longus due to Fracture of the distal radius: A Case Report

Affiliations
  • 1Department of Orthopedic Surgery, Soonchunhyang University Kumi Hospital, Korea.

Abstract

After distal radius fracture, delayed rupture of extensor pollicis longus is rare. It is known that delayed rupture of extensor pollicis longus tendon result from undisplaced distal radius fracture. We have experienced a case of rupture of the extensor pollicis longus tendon after undisplaced distal radius fracture, and treated with palmaris longus tendon graft. the result were satisfactory without complications.

Keyword

Extensor Pollicis Longus; Undisplaced Distal Radius fracture

MeSH Terms

Radius Fractures
Radius*
Rupture*
Tendons
Transplants