Korean J Anesthesiol.  2004 Jun;46(6):747-750. 10.4097/kjae.2004.46.6.747.

A Case of Pulmonary Artery Catheter Malposition after the Weaning of Cardiopulmonary Bypass: A case report

Affiliations
  • 1Department of Anesthesiology and Pain Medicine, School of Medicine, Keimyung University, Daegu, Korea.

Abstract

A 79-year old male with angina underwent emergent coronary artery bypass graft. After the induction of anesthesia, a pulmonary artery catheter (PAC) was placed via the right subclavian vein. At weaning from cardiopulmonary bypass, the pulmonary artery wave form did not appear on the monitor. We pulled and pushed the PAC repeatedly. However, we could observed no pulmonary artery pressure; the PAC was not pulled out at the 42 cm from the distal tip. Chest X-ray revealed a malposed PAC into the ipsilateral internal jugular vein. No deleterious complications were observed either during the immediate or later postanesthetic period.

Keyword

complication; monitoring; pulmonary artery catheter

MeSH Terms

Aged
Anesthesia
Cardiopulmonary Bypass*
Catheters*
Coronary Artery Bypass
Humans
Jugular Veins
Male
Pulmonary Artery*
Subclavian Vein
Thorax
Transplants
Weaning*
Full Text Links
  • KJAE
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles