Korean J Thorac Cardiovasc Surg.  2004 Apr;37(4):342-348.

Factors Influencing on Early Patency Rate of Autogenous Arteriovenous Fistula for Hemodialysis

Affiliations
  • 1Department of Thoracic and Cardiovascular Surgery, Mok-Dong Hospital, College of Medicine, Ewha Womans University, Korea. jhahn@mm.ewha.ac.kr

Abstract

BACKGROUND: It is very important for hemodialysis in patients with end stage renal disease to obtain vascular access that resists repeated punctures and maintains adequate blood flow. This study was designed to indentify factors that may influence early patency rate of autogenous arteriovenous fistula. MATERIAL AND METHOD: 49 cases in 47 patients who underwent radiocephalic fistula formation in our hospital from June 2002 through May 2003 were reviewed and analyzed. RESULT: The early patency rate was 79.6%. Age, sex, hypertension, and diabetes mellitus were not significant factors for patency. Body mass index and duration of hypertension and diabetes did not influence the early results either. Cephalic vein diameter measured preoperatively and blood flow at radiocephalic fistula were significantly positive correlative factors. Groups with the vein diameter less than 2.7 mm, or with the blood flow less than 100 mL/min had significantly lower early patency rate than the other groups.
CONCLUSION
To improve early patency rate of radiocephalic fistula, large sized cephalic vein should be selected and if the intraoperative flow at radiocephalic fistula is less than 100 mL/min, another arteriovenous fistula formation should be considered.

Keyword

Arteriovenous fistula, surgical; Hemodialysis; Fistula

MeSH Terms

Arteriovenous Fistula*
Body Mass Index
Diabetes Mellitus
Fistula
Humans
Hypertension
Kidney Failure, Chronic
Punctures
Renal Dialysis*
Veins