Korean J Obstet Gynecol.  2009 Jan;52(1):129-132.

Two cases of small bowel herniation through 5 mm trocar site following removal of drains after gynecologic laparoscopy

Affiliations
  • 1Department of Obstetrics and Gynecology, The Catholic University of Korea, Daejeon, Korea. gom@catholic.ac.kr
  • 2Department of General Surgery, The Catholic University of Korea, Daejeon, Korea.

Abstract

After laparoscopic surgery, most cases of incisional hernia occur when a trocar greater than 10 mm is used and this rarely occurs when a 5 mm trocar is used. We recently experienced two cases of incisional herniation at a 5 mm port site in connection with withdrawal of the drain after laparoscopic procedure.

Keyword

Laparoscopy; 5 mm trocar; Port site herniation; Drain