Korean J Anesthesiol.  1994 Jul;27(7):778-781. 10.4097/kjae.1994.27.7.778.

A Depth of the Tuohy Needle in Thoracic Epidural Anesthesia

Affiliations
  • 1Department of Anesthesiology, Samsung Medical Center, Seoul, Korea.
  • 2Department of Anesthesiology, Dankuk University College of Medicine, Chunan, Korea.
  • 3Department of Anesthesiology, Seoul National University College of Medicine, Seoul, Korea.

Abstract

A depth of the Tuohy needle in thoracic epidural anesthesia was measured in 101 patients undergoing thoracotomy. The patients were divided into two groups, which were received epidural anesthesia in T5-6 and T6-7 levels. The patient's age, sex, height and most recent antenatal or preoperative weight were obtained before measuring the needle depth. The PI (ponderal index) was calculated by dividing weight (Kg) by height (m). In patients of T5-6 group, the mean depth was found to be 6.14 cm which had no correlation with any other measurements. In patients of T6-7 group, the mean depth was found to be 6.16 cm which had no correlation with any other measurements.

Keyword

Depth of the Tuohy Needle; Thoracic Epidural Anesthesia

MeSH Terms

Anesthesia, Epidural*
Humans
Needles*
Thoracotomy