Abstract

BACKGROUND
Perfusion scintigraphy with dipyridamole have been reported to be useful for diagnosis of coronary artery disease and the assessment of the presence and extent of myocardium at ischemic risk, especially in patients who can not undergo dynamic exercise testing. Dipyridamole, pharmacologic coronary vasodilator, also induces fall in blood pressure and rise in heart rate. The purpose of this study was to answer the question if dipyridamole induced peripheral hemodynamic responses were related to chest pain, ST changes on EKG, scintigraphic defect or extent of coronary stenosis.
METHODS
Dipyridamole 99mTc-MIBI myocardial scintigraphy and coronary angiography on 43 subjects who were suspected to have coronary artery disease. The peripheral hemodynamic response was graded as absent(group 0) if there was a < or =10mm fall in systolic blood pressure (SBP) and/or < or =10 beats/min rise in geart rate(HR) ; moderate(group 1) if there was >10 but < or =20mm fall in SBP and/or >10 but < or =20 beats/min rise in HR ; and marked (group 2) if there was >20mm fall in SBP and/or >20 beats/min rise in HR.
RESULTS
The overall diagnostic sensitivity and specificity for coronary artery disease of dipyridamole perfusion scintigraphy were 68%, 83% while per vessel sensitivity and specificity for coronary artery disease were 66%, 97%. The numbers of induced chest pain and ischemic ST changes among hemodynamic subgroups, were 40%, 40% in group 0, 33%, 27% in group 1 and 50%, 40% in group 2 without significant difference in each hemodynamic subgroups. Either the numbers of diseased coronary arteries or the numbers of patients demonstrationg reversible scintigraphic defects were not statically different among each subgroups.
CONCLUSION
Although the peripheral hemodynamic response dose not always correlate with its central coronary effect but dipyridamlole 99mTc-MIBI myocardial perfusion scintigraphy is an useful test for diagnosis of coronary artery disease.

Keyword

Dipyridamole 99mTc-MIBI Scintigraphy; Coronary artery disease; Peripheral hemodynamic response

MeSH Terms

Blood Pressure
Chest Pain
Coronary Angiography
Coronary Artery Disease*
Coronary Stenosis
Coronary Vessels*
Diagnosis
Dipyridamole*
Electrocardiography
Exercise Test
Heart Rate
Hemodynamics*
Humans
Myocardial Perfusion Imaging
Myocardium
Perfusion Imaging
Sensitivity and Specificity
Dipyridamole