J Korean Ophthalmol Soc.  2014 Feb;55(2):190-195. 10.3341/jkos.2014.55.2.190.

Comparison of Intraocular Straylight in Patients with Clear and Photochromic Intraocular Lenses

Affiliations
  • 1Department of Ophthalmology, Sahmyook Seoul Hospital, Seoul, Korea.
  • 2Department of Ophthalmology and Visual Science, The Catholic University of Korea College of Medicine, Seoul, Korea. eyedoc@catholic.ac.kr

Abstract

PURPOSE
To compare visual acuity and intraocular straylight after implantation of clear and photochromic intraocular lenses (IOLs) in a mesopic lighting condition.
METHODS
Clear IOLs were implanted in 95 eyes of 72 patients (clear IOL group), and photochromic IOLs were implanted in 22 eyes of 16 patients (photochromic IOL group). Best-corrected visual acuity (BCVA) was measured indoors before surgery and 1 month after surgery. Straylight values were measured indoors before surgery and 1 and 2 months after surgery using the C-quant straylight meter (Oculus GmbH, Wetzlar, Germany).
RESULTS
There were no significant differences between the 2 groups in BCVA at 1 month postoperatively (p = 0.587). Mean straylight values of clear and photochromic IOL groups were 2.76 +/- 1.89 log (s) and 2.88 +/- 2.04 log (s) preoperatively, 1.39 +/- 0.84 log (s) and 1.32 +/- 0.26 log (s) at 1 month postoperatively, and 1.43 +/- 0.92 log (s) and 1.45 +/- 0.50 log (s) at 2 months postoperatively. There were no significant differences between the 2 groups in indoor straylight values (p = 0.778, 0.709, 0.929, before surgery, 1 and 2 months after surgery respectively). Repeated-measure analysis of straylight values also showed no significant difference between the 2 groups (p > 0.05).
CONCLUSIONS
There were no significant differences in BCVA and straylight values between clear and photochromic IOL groups under a mesopic light condition. Therefore, photochromic IOL could be suitable choice for cataract patients who spend significant time under mesopic conditions.

Keyword

Blue light; C-quant; Mesopic; Photochromic intraocular lens; Straylight

MeSH Terms

Cataract
Humans
Lenses, Intraocular*
Visual Acuity

Figure

  • Figure 1. Comparison of mean and 95% confidence interval (CI) of straylight value in clear and photochornomic IOL group before and after cataract surgery. No statistically significant differences in straylight values of two groups at pre-operatively, 1 month, and 2 months postoperatively (p < 0.001, p < 0.001, p = 0.568).


Reference

References

1. Gaillard ER, Zheng L, Merriam JC, Dillon J.Age-related changes in the absorption characteristics of the primate lens. Invest Ophthalmol Vis Sci. 2000; 41:1454–9.
2. Margrain TH, Boulton M, Marshall J, Sliney DH.Do blue light fil-ters confer protection against age-related macular degeneration? Prog Retin Eye Res. 2004; 23:523–31.
Article
3. Norren DV, Vos JJ.Spectral transmission of the human ocular media. Vision Res. 1974; 14:1237–44.
Article
4. Sparrow JR, Miller AS, Zhou J.Blue light-absorbing intraocular lens and retinal pigment epithelium protection in vitro. J Cataract Refract Surg. 2004; 30:873–8.
Article
5. Pollack A, Marcovich A, Bukelman A, Oliver M.Age-related mac-ular degeneration after extracapsular cataract extraction with intra-ocular lens implantation. Ophthalmology. 1996; 103:1546–54.
Article
6. Fletcher AE, Bentham GC, Agnew M. . Sunlight exposure, an-tioxidants, and age-related macular degeneration. Arch Ophthalmol. 2008; 126:1396–403.
Article
7. Ernest PH.Light-transmission-spectrum comparison of foldable intraocular lenses. J Cataract Refract Surg. 2004; 30:1755–8.
Article
8. Muftuoglu O, Karel F, Duman R.Effect of a yellow intraocular lens on scotopic vision, glare disability, and blue color perception. J Cataract Refract Surg. 2007; 33:658–66.
Article
9. Cionni RJ, Tsai JH.Color perception with AcrySof natural and AcrySof single-piece intraocular lenses under photopic and mes-opic conditions. J Cataract Refract Surg. 2006; 32:236–42.
Article
10. Mester U, Holz F, Kohnen T. . Intraindividual comparison of a blue-light filter on visual function: AF-1 (UY) versus AF-1 (UV) intraocular lens. J Cataract Refract Surg. 2008; 34:608–15.
Article
11. Mainster MA.Blue-blocking intraocular lenses and pseudophakic scotopic sensitivity. J Cataract Refract Surg. 2006; 32:1403–4.
Article
12. Mainster MA, Turner PL.Blue-blocking intraocular lenses: myth or reality? Am J Ophthalmol. 2009; 147:8–10.
Article
13. Werner L, Mamalis N, Romaniv N. . New photochromic foldable intraocular lens: preliminary study of feasibility and biocompatibility. J Cataract Refract Surg. 2006; 32:1214–21.
Article
14. Franssen L, Coppens JE, van den Berg TJ.Compensation compar-ison method for assessment of retinal straylight. Invest Ophthalmol Vis Sci. 2006; 47:768–76.
Article
15. Van Den Berg TJ, Van Rijn LJ, Michael R. . Straylight effects with aging and lens extraction. Am J Ophthalmol. 2007; 144:358–63.
Article
16. Lee SY, Oh JH.Straylight in normal and cataractous eyes of Koreans. J Korean Ophthalmol Soc. 2011; 52:182–9.
Article
17. van den Berg TJ.On the relation between glare and straylight. Doc Ophthalmol. 1991; 78(3-4):177–81.
Article
18. van Rijn LJ, Nischler C, Gamer D. . Measurement of stray light and glare: comparison of Nyktotest, Mesotest, stray light meter, and computer implemented stray light meter. Br J Ophthalmol. 2005; 89:345–51.
Article
19. Mennig M, Fries K, Lindenstruth M, Schmidt H.Development of fast switching photochromic coatings on transparent plastics and glass. Thin Solid Films. 1999; 351:230–4.
Article
20. Seefeldt B, Kasper R, Beining M. . Spiropyrans as molecular optical switches. Photochem Photobiol Sci. 2010; 9:213–20.
Article
21. Klajn R.Spiropyran-based dynamic materials. Chem Soc Rev. 2013; 43:148–84.
Article
22. van der Meulen IJ, Gjertsen J, Kruijt B. . Straylight measure-ments as an indication for cataract surgery. J Cataract Refract Surg. 2012; 38:840–8.
Article
23. Wang H, Wang J, Fan W, Wang W.Comparison of photochromic, yellow, and clear intraocular lenses in human eyes under photopic and mesopic lighting conditions. J Cataract Refract Surg. 2010; 36:2080–6.
Article
24. Bhattacharjee H, Bhattacharjee K, Medhi J.Visual performance: Comparison of foldable intraocular lenses. J Cataract Refract Surg. 2006; 32:451–5.
Article
25. Mester U, Holz F, Kohnen T. . Intraindividual comparison of a blue-light filter on visual function: AF-1 (UY) versus AF-1 (UV) intraocular lens. J Cataract Refract Surg. 2008; 34:608–15.
Article
26. Leibovitch I, Lai T, Porter N. . Visual outcomes with the yel-low intraocular lens. Acta Ophthalmol Scand. 2006; 84:95–9.
Article
27. Zhu XF, Zou HD, Yu YF. . Comparison of blue light-filtering IOLs and UV light-filtering IOLs for cataract surgery: a meta- analysis. PLoS One. 2012; 7:e33013.
28. Ao M, Chen X, Huang C. . Color discrimination by patients with different types of light-filtering intraocular lenses. J Cataract Refract Surg. 2010; 36:389–95.
Article
Full Text Links
  • JKOS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles