J Korean Ophthalmol Soc.  2016 Mar;57(3):399-404. 10.3341/jkos.2016.57.3.399.

Second-Eye Refractive Error Depending on the Reflection Rate of First-Eye Refractive Error in Cataract Surgeries

Affiliations
  • 1Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea. tychung@skku.edu

Abstract

PURPOSE
To evaluate the reflection rate of the first eye in order to minimize the real refractive error in the second eye in bilateral consecutive cataract surgeries.
METHODS
A retrospective analysis was performed with 248 patients who underwent bilateral sequential uncomplicated phacoemulsification and posterior chamber intraocular lens implantation. Predicted spherical equivalent was compared with postoperative spherical equivalent, and the range of real refractive error was analyzed by calculating the reflection rate of the first eye.
RESULTS
When the difference between predicted spherical equivalent and postoperative spherical equivalent was greater than 0.5 D as calculated with the formula of Sanders-Retzlaff-Kraff Theoretical (SRK)-T and SRK II, application of 50-60%, 40-50% of the difference of the first eye was high probability to reduce the second-eye real refractive error (75%, 100%).
CONCLUSIONS
Application of 40-60% of the real refractive error in the first-eye can minimize the real refractive error in the second-eye in bilateral sequential cataract surgeries.

Keyword

Bilateral consecutive cataract surgery; Reflection rate; Refractive error

MeSH Terms

Cataract*
Humans
Lens Implantation, Intraocular
Phacoemulsification
Refractive Errors*
Retrospective Studies

Reference

References

1. Jabbour J, Irwig L, Macaskill P, Hennessy MP. Intraocular lens power in bilateral cataract surgery: whether adjusting for error of predicted refraction in the first eye improves prediction in the second eye. J Cataract Refract Surg. 2006; 32:2091–7.
Article
2. Covert DJ, Henry CR, Koenig SB. Intraocular lens power selection in the second eye of patients undergoing bilateral, sequential cataract extraction. Ophthalmology. 2010; 117:49–54.
Article
3. Jivrajka RV, Shammas MC, Shammas HJ. Improving the second-eye refractive error in patients undergoing bilateral sequential cataract surgery. Ophthalmology. 2012; 119:1097–101.
Article
4. Mamalis N. Intraocular lens power accuracy: how are we doing? J Cataract Refract Surg. 2003; 29:1–3.
Article
5. Brick DC. Risk management lessons from a review of 168 cataract surgery claims. Surv Ophthalmol. 1999; 43:356–60.
Article
6. Elder MJ. Predicting the refractive outcome after cataract surgery: the comparison of different IOLs and SRK-II v SRK-T. Br J Ophthalmol. 2002; 86:620–2.
Article
7. Lam AK, Chan R, Pang PC. The repeatability and accuracy of axial length and anterior chamber depth measurements from the IOLMaster. Ophthalmic Physiol Opt. 2001; 21:477–83.
8. McEwan JR, Massengill RK, Friedel SD. Effect of keratometer and axial length measurement errors on primary implant power calculations. J Cataract Refract Surg. 1990; 16:61–70.
Article
9. Percival SP, Vyas AV, Setty SS, Manvikar S. The influence of implant design on accuracy of postoperative refraction. Eye (Lond). 2002; 16:309–15.
Article
10. Shammas HJ, Chan S. Precision of biometry, keratometry, and refractive measurements with a partial coherence interferometry-keratometry device. J Cataract Refract Surg. 2010; 36:1474–8.
Article
11. Aristodemou P, Knox Cartwright NE, Sparrow JM, Johnston RL. First eye prediction error improves second eye refractive outcome results in 2129 patients after bilateral sequential cataract surgery. Ophthalmology. 2011; 118:1701–9.
12. Olsen T. Use of fellow eye data in the calculation of intraocular lens power for the second eye. Ophthalmology. 2011; 118:1710–5.
Article
13. Ladas JG, Stark WJ. Improving cataract surgery refractive outcomes. Ophthalmology. 2011; 118:1699–700.
Article
14. Olsen T. Sources of error in intraocular lens power calculation. J Cataract Refract Surg. 1992; 18:125–9.
Article
15. Olsen T. Prediction of the effective postoperative (intraocular lens) anterior chamber depth. J Cataract Refract Surg. 2006; 32:419–24.
Article
Full Text Links
  • JKOS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr