1. Troost R, Vogel A, Beck S, et al. Clinical comparison of two intraocular pressure measurement methods: SmartLens dynamic observing tonography versus Goldmann. Graefes Arch Clin Exp Ophthalmol. 2001; 239:889–92.
Article
2. Whitacre MM, Stein RA, Hassanein K. The effect of corneal thickness on applanation tonometry. Am J Ophthalmol. 1993; 115:592–6.
Article
3. Wolfs RCW, Klaver CC, Vingerling JR, et al. Distribution of central corneal thickness and its association with intraocular pressure: the Rotterdam study. Am J Ophthalmol. 1997; 123:767–72.
Article
4. Doughty MJ, Saman ML. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol. 2000; 44:367–408.
5. Ehlers N, Bramsen T, Sperling S. Applanation tonometry and central corneal thickness. Acta Ophthalmol (Copenh). 1975; 53:1974–83.
Article
6. Brandt JD, Beiser JA, Kass MA, Gordon MO. Central corneal thickness in the Ocular Hypertension Treatment Study (OHTS). Ophthalmology. 2001; 108:1779–88.
Article
7. Gordon MO, Beiser JA, Brandt JD, et al. The Ocular Hypertension Treatment study: baseline factors that predict the onset of primary open angle glaucoma. Arch Ophthalmol. 2002; 120:714–20.
8. Herndon LW, Allingham R, Choudhri SA, et al. Central corneal thickness innormal, glaucomatous, and ocular hypertensive eyes. Arch Ophthalmol. 1997; 115:1137–41.
9. Siganos DS, Papasterigiou GI, Moedas C. Assessment of the Pascal dynamic contour tonometer in monitoring intraocular pressure in unoperated eyes and eyes after LASIK. J Cataract Refract Surg. 2004; 30:746–51.
Article
10. Kaufman C, Bachmann LM, Thiel MA. Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis. Invest Ophthalmol Vis Sci. 2003; 44:3790–4.
11. Kaufmann C, Bachmann LM, Thiel MA. Comparison of dynamic contour tonometry with Goldmann applanation tonometry. Invest Ophthalmol Vis Sci. 2004; 45:3118–21.
Article
12. Kniestedt C, Nee M, Stamper RL. Dynamic contour tonometry (DCT) and its dependence on corneal hydration in human cadaver eyes. Arch Ophthalmol. 2004; 122:1287–93.
13. Wirthlin AC, Siganos DD, Papastergiou G, et al. Dynamic contour tonometry for IOP measurement after LASIK, a comparison with Goldmann tonometry. Synopsis of paper presented at DOC, Nurenberg. 2002.
14. Duba I, Wirthlin AC. Dynamic contour tonometry for post-LASIK intraocular pressure measure measurements. Klin Monatsbl Augenheilkd. 2004; 221:347–50.
15. Fresco BB. A new tonometer-the pressure phosphene tonometer: clinical comparison with Goldmann tonometry. Ophthalmology. 1998; 105:2123–6.
16. Whitacre MM, Stein RA, Hassanein K. The effect of corneal thickness on applanation tonometry. Am J Ophthalmol. 1993; 115:592–6.
Article
17. Stodtmeister R. Applanation tonometry and correlation according to corneal thickness. Acta Ophthalmol Scand. 1998; 76:319–24.
18. Velten IM, Bergua A, Horn FK, et al. Central corneal thickness in normal eyes, patients with ocular hypertension, normal-pressure and open-angle glaucomas-a study. Klin Monatsbl Augenheilkd. 2001; 218:466.
19. Ventura AC, Bohnke M, Mojon DS. Central corneal thickness in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension. Br J Ophthalmol. 2001; 85:792–5.
20. Grieshaber MC, Schoetzau A, Zawinka C, et al. Effect of central corneal thickness on dynamic contour tonometry and Goldmann applanation tonometry in primary open-angle glaucoma. Arch Ophthalmol. 2007; 125:740–4.
Article
21. Francis BA, Hsieh A, Lai MY, et al. Los Angeles Latino Eye Study Group. Effects of corneal thickness, corneal curvature, and intraocular pressure level on Goldmann applanation tonometry and dynamic contour tonometry. Ophthalmology. 2007; 114:20–6.
22. Martinez-de-la-Casa JM, Garcia-Feijoo J, Vico E, et al. Effect of corneal thickness on dynamic contour, rebound, and goldmann tonometry. Ophthalmology. 2006; 113:2156–62.
Article