J Korean Ophthalmol Soc.  2008 Jan;49(1):143-147. 10.3341/jkos.2008.49.1.143.

Intraoperative Adjustment in Horizontal Strabismus Surgery Using Corneal Reflex

Affiliations
  • 1The Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea. 491209@yumc.yonsei.ac.kr
  • 2Department of Ophthalmology, Ajou University School of Medicine, Suwon, Korea.
  • 3Department of Ophthalmology, College of Medicine, Soonchunhyang University, Bucheon, Korea.

Abstract

PURPOSE: Using corneal reflex, we performed intraoperative adjustments in horizontal strabismus patients who had very poor visual acuities with good compliance and analyzed various aspects of intraoperative adjustment.
METHODS
We retrospectively reviewed the records of patients with horizontal strabismus who underwent intraoperative adjustment using corneal reflex from May 1997 to April 2005. We evaluated various aspects of intraoperative adjustment.
RESULTS
Fifty-five patients (40 exotropes, 15 esotropes) were included in our study. 11 of 40 extropes (27.5%) and 4 of 15 esotropes (26.7%) eventually underwent operations that were adjusted intraoperatively. Successful results were seen in 35 of 40 exotropes (87.5%) and 8 of 15 esotropes (53.3%). Fifteen patients (27.3%) received intraoperative adjustments, and of these patients 11 (20.0%) who had successful results would have experienced either undercorrection or overcorrection if their operation were performed as scheduled. Four patients underwent operation on one muscle rather than on the scheduled two muscles. All 4 of these patients (100%) would have experienced significantly large overcorrection had they not received intraoperative adjustment.
CONCLUSIONS
Patients who would have had difficulty with fixation due to low visual acuity could avoid under- or overcorrection and are expected to have higher success rates because of intraoperative adjustment using corneal reflex.

Keyword

Corneal reflex; Horizontal strabismus; Intraoperative adjustment

MeSH Terms

Compliance
Humans
Muscles
Reflex
Retrospective Studies
Strabismus
Visual Acuity

Reference

References

1. Jin YH, Kwak CH. Intraoperative adjustment with topical anesthetics in strabismus surgery. J Korean Ophthalmol Soc. 1992; 33:60–4.
2. Jampolsky A. Strabismus reoperation techniques. Trans Am Acad Ophthalmol Otolaryngol. 1975; 79:704–11.
3. Jampolsky A. Current technique of adjustable strabismus surgery. Am J Ophthalmol. 1979; 88:406–18.
4. Crawford JS. Adjustable sutures in strabismus. Trans New Orleans Acad Ophthalmol. 1986; 34:501–16.
5. Helveston EM, Ellis FD. Adjustable sutures for horizontal and vertical strabismus. Am Orthopt J. 1978; 28:18–23.
Article
6. McNeer KW. Adjustable sutures of the vertical recti. J Pediatr Ophthalmol Strabismus. 1982; 19:259–64.
Article
7. Docherty PT. Paralytic strabismus correction by adjustable suture technique. Br J Ophthalmol. 1984; 68:353–9.
Article
8. Waterhouse WJ, Enzenauer RW, Martyak AP, et al. Successful strabismus surgery in a child with Moebius syndrome. Ann Ophthalmol. 1993; 25:292–4.
9. Wisnicki HJ, Repka MX, Guyton DL, et al. Reoperation rate in adjustable strabismus surgery. Pediatr Ophthalmol Strabismus. 1988; 25:112–4.
Article
10. Kim SD, Yang YS, Kim JD. Tolerance of patients and postoperative results: topical anesthesia for strabismus surgery. J Pediatr Ophthalmol Strabismus. 2000; 37:344–8.
Article
11. Chin HS, Kim HS, Lee JB, et al. The effect of intraoperative adjustment strabismus surgery under topical anesthesia. J Korean Ophthalmol Soc. 1996; 37:1915–9.
12. Jones R, Eskridge JB. The Hirschberg test: a re-evaluation. Am J Optom Arch Am Acad Optom. 1970; 47:105–14.
13. Wick B, London R. The Hirschberg test: analysis from birth to age 5. J Am Optom Assoc. 1980; 51:1009–10.
14. Mims JL 3rd, Wood RC. Proportional (fractional) displacement of the Hirschberg corneal light reflection (test): a new easily memorized aid for strabometry; photogrammetric standardization (calibration). Binocul Vis Strabismus Q. 2002; 17:192–8.
15. Choi RY, Kushner BJ. The accuracy of experienced strabismologists using the Hirschberg and Krimsky tests. Ophthalmology. 1998; 105:1301–6.
16. Boo SD, Lee JB. Comparison of Hirschberg test with prism and alternate cover test in measuring the ocular deviation. J Korean Ophthalmol Soc. 1993; 34:78–82.
17. Johnson JA, Barlow JM, Tilson G. Early surgery in intermittent exotropia. Am J Ophthalmol. 1977; 84:689–94.
18. Hardesty HH, Boynton JR, Keenan JP. Treatment of intermittent exotropia. Arch Ophthalmol. 1978; 96:268–74.
Article
19. Lee JB, Kim HS, Han SH, Cho KW. Surgical result of intermittent exotropia: Comparison of sensory anomaly. J Korean Ophthalmol Soc. 1993; 34:1247–50.
20. Lew H, Lee JB, Kim TK. Comparison of surgical results between bilateral rectus muscle recessions and lateral rectus muscle recession and medial rectus muscle resection in exotropia. J Korean Ophthalmol Soc. 1995; 36:115–9.
21. Hakim OH, El-Hag YG, Haikal MA. Strabismus surgery under augmented topical anesthesia. J AAPOS. 2005; 9:279–84.
Article
22. Chang YH, Ryu IH, Han SH, et al. Intraoperative adjustment in strabismus surgery under topical anesthesia. Yonsei Med J. 2006; 47:667–71.
Article
23. Weston B, Enzenauer RW, Kraft SP, et al. Stability of the postoperative alignment in adjustable suture strabismus surgery. J Pediatr Ophthalmol Strabismus. 1991; 28:206–11.
Full Text Links
  • JKOS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles