J Korean Ophthalmol Soc.  1991 Feb;32(2):184-189.

Anterior Chamber Tube Shunt to a Surgical Membrane

Affiliations
  • 1Department of Ophthalmology, College of Medicine, Seoul National University, Seoul, Korea.

Abstract

Ahn et al.(1989) reported that glaucoma tube shunt surgery using 0.1 mm thickness expanded polytetrafluoroethylene(e-PTFE) as a template controlled the intraocular pressure successfully. But it requires the placement of intraluminal suture in the silicone tube to prevent early postoperative hypotony. To overcome this disadvantage, we modified the template by putting the posterior end of the silicone tube between the two-fold e-PTFE membrane and implanted it in 5 refractory glaucoma patients. The intraocular pressure was controlled without complications such as early hypotony, flat anterior chamber, and choroidal detachment.

Keyword

early postoperative hypotony; glaucoma; intraocular pressure; silicone tube; two-fold expanded polytetrafluoroethylene

MeSH Terms

Anterior Chamber*
Choroid
Glaucoma
Humans
Intraocular Pressure
Membranes*
Silicones
Sutures
Silicones
Full Text Links
  • JKOS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr