J Korean Ophthalmol Soc.  1986 Aug;27(4):561-565.

The Results of Modified Trabeculectomy with a Slicone Tube for Eyes with Neovascular Glaucoma

Affiliations
  • 1Department of Ophthalmology, Yonsei College of Medicine, Seoul, Korea.

Abstract

Neovascular glaucoma is considered to be one of the most difficult forms of glaucoma to control. In neovascular glaucoma fibrovascular tissue grows over the surface of the iris and trabecular meshwork. Many modified filtering surgery with artificial drainage devices have been tried in attempts to maintain openings for aqueous humor to leave the eye. Modified trabeculectomy was performed with inexpensive easily available simple silicone tube in 8 eyes with neovascular glaucma. Of the 8 eyes, 6 had postopeoative intraocular pressures lower rhan 25mmHg through a mean follow-up period of 6 months.


MeSH Terms

Aqueous Humor
Drainage
Filtering Surgery
Follow-Up Studies
Glaucoma
Glaucoma, Neovascular*
Intraocular Pressure
Iris
Silicones
Trabecular Meshwork
Trabeculectomy*
Silicones
Full Text Links
  • JKOS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles