J Korean Radiol Soc.  1998 Apr;38(4):585-587. 10.3348/jkrs.1998.38.4.585.

Transarterial Embolization of a Carotid Cavernous Fistula with Guglielmi Detachable Coils: A Case Report

Affiliations
  • 1Department of Diagnostic Radiology, Wallace Memorial Baptist Hospital, Korea.
  • 2Department of Diagnostic Radiology, College of Medicine, Pusan National University, Korea.

Abstract

In the management of carotid cavernous fistula, detachable balloon has become the treatment of choice.However, technical difficulties are not uncommon, and transarterial balloon embolization fail in 5% to 10% ofcases. Failure occurs because in some patients, the fistula orifice may be too small to allow entry. Using atracker catheter system with Guglielmi detachable coils, we achieved successful transarterial occlusion of acarotid cavernous fistula with a small fistula.

Keyword

Fistula, carot6id-cavernous; Carotid arteries, therapentic blockade