J Korean Acad Prosthodont.  2000 Oct;38(5):631-639.

CLINICAL STUDY OF ENDOSSEOUS HYDROXYAPATITE COATED IMPLANTS

Affiliations
  • 1Department of Prosthodontics, College of Dentistry, Youngdong Severance Hospital, Yonsei University, Korea.

Abstract

Root-form endosseous implants which are in use today have a variety of materials, designs and surface characteristics. Among them, pure titanium surface implants and titanium matrix coated with HA are popular as well as are available in many studies. Rate of clinical success is obviously lower in jaw with cancellous bone than dense bone., In order to increase the rate of success in poor bone quality. More advanced techniques of implant surgery and surface treatment of implant fixture body have been developed. As a successful result, the installation of HA coated implant in bone quality type III or IV became highly successful. Since most clinical studies were performed without knowing the characteristics of HA coated implants, it has been impossible to come up with proper clinical data. Therefore the characterization of HA coated implants is essential to understand long term clinical performance and the predictability of HA coated implant system. Our results showed that HA coated implants had the success rate at 93.7% in bone quality type III, IV for 3.8 years, and the fixture of Steri-Oss showed more stability with time.


MeSH Terms

Durapatite*
Jaw
Titanium
Durapatite
Titanium
Full Text Links
  • JKAP
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles