J Korean Acad Periodontol.  2007 Sep;37(3):585-597. 10.5051/jkape.2007.37.3.585.

The effect of conditioning by Tetracycline-HCl on implant surface: The SEM study and surface roughness measurements: RBM surface

Affiliations
  • 1Department of Periodontology and Institute of Oral Biology, School of Dentistry, Kyung Hee University, Korea. jbpark@khu.ac.kr

Abstract

The present study was performed to evaluate the effect of Tetracycline-HCl and Saline on the change of implant surface microstructure and surface roughness according to application time. Implants with resorbable blasting media surface were utilized. Before test all 13 implants were measured surface roughness. Among them, 6 implants were rubbed with 50mg/ml Tetracycline-HCl solution and other 6 implants with saline for 1/2min., 1min., 1 1/2min., 2min., 2 1/2min and 3min. Then, specimens were processed for scanning electron microscopic observation and surface roughness after test. The results of this study were as follows. 1. Control group showed a few irregular, rough, uneven surface with crater-like depression. 2. The test group with Tetracycline-HCl conditioning showed an altered surface when Tetracycline-HCl was applied for 30secs, and showed a various surface alteration as application times go on. 3. The test group with Saline conditioning showed no significant surface differences and surface roughness. 4. The significant increase of Ra value was showed when Tetracycline-HCl was applied for 30secs. In conclusion, the 50mg/ml Tetracycline-HCl must not be applied for the RBM surface implant for surface treatment.

Keyword

tetracycline-HCl; RBM implant surface; surface roughness

MeSH Terms

Depression
Full Text Links
  • JKAPE
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr